SCLS464A September   2002  – January 2015 CD74HC4051-EP

PRODUCTION DATA.  

  1. Features
  2. Applications
  3. Description
  4. Revision History
  5. Pin Configuration And Functions
  6. Specifications
    1. 6.1 Absolute Maximum Ratings
    2. 6.2 ESD Ratings
    3. 6.3 Recommended Operating Conditions
    4. 6.4 Thermal Information
    5. 6.5 Electrical Characteristics
    6. 6.6 Analog Channel Characteristics
    7. 6.7 Switching Characteristics
    8. 6.8 Typical Characteristics
      1. 6.8.1 Recommended Operating Area as a Function of Supply Voltages
  7. Parameter Measurement Information
  8. Detailed Description
    1. 8.1 Overview
    2. 8.2 Functional Block Diagram
    3. 8.3 Feature Description
    4. 8.4 Device Functional Modes
  9. Application and Implementation
    1. 9.1 Application Information
      1. 9.1.1 TTL-to-HC Interface
    2. 9.2 Typical Application
      1. 9.2.1 Design Requirements
      2. 9.2.2 Detailed Design Procedure
      3. 9.2.3 Application Curves
  10. 10Power Supply Recommendations
  11. 11Layout
    1. 11.1 Layout Guidelines
    2. 11.2 Layout Example
  12. 12Device And Documentation Support
    1. 12.1 Trademarks
    2. 12.2 Electrostatic Discharge Caution
    3. 12.3 Glossary
  13. 13Mechanical, Packaging, and Orderable Information

パッケージ・オプション

デバイスごとのパッケージ図は、PDF版データシートをご参照ください。

メカニカル・データ(パッケージ|ピン)
  • D|16
サーマルパッド・メカニカル・データ
発注情報

6 Specifications

6.1 Absolute Maximum Ratings

over operating free-air temperature range (unless otherwise noted) (1)
MIN MAX UNIT
VCC – VEE(2) Supply voltage –0.5 10.5 V
VCC –0.5 7
VEE 0.5 –7
IIK Input clamp current (VI < –0.5 V or VI > VCC + 0.5 V) –20 20 mA
IOK Output clamp current (VO < VEE – 0.5 V or VO > VCC + 0.5 V) –20 20 mA
Switch current (VI > VEE – 0.5 V or VI < VCC + 0.5 V) –25 25 mA
Continuous current through VCC or GND –50 50 mA
IEE VEE current 0 20 mA
θJA Package thermal impedance(3) 73 °C/W
TJ Maximum junction temperature 150 °C
Tstg Storage temperature –65 150 °C
(1) Stresses beyond those listed under Absolute Maximum Ratings may cause permanent damage to the device. These are stress ratings only, which do not imply functional operation of the device at these or any other conditions beyond those indicated under Recommended Operating Conditions. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
(2) All voltages referenced to GND unless otherwise specified.
(3) The package thermal impedance is calculated in accordance with JESD 51-7.

6.2 ESD Ratings

VALUE UNIT
V(ESD) Electrostatic discharge Human body model (HBM), per ANSI/ESDA/JEDEC JS-001, all pins(1) ±2000 V
Charged device model (CDM), per JEDEC specification JESD22-C101, all pins(2) ±500
(1) JEDEC document JEP155 states that 500-V HBM allows safe manufacturing with a standard ESD control process.
(2) JEDEC document JEP157 states that 250-V CDM allows safe manufacturing with a standard ESD control process.

6.3 Recommended Operating Conditions(1)

over operating free-air temperature range (unless otherwise noted)
MIN NOM MAX UNIT
VCC Supply voltage(2) 2 6 6 V
Supply voltage, VCC – VEE (see Figure 4) 2 10 10 V
VEE Supply voltage, (see (2) and Figure 5) 0 –6 –6 V
VIH High-level input voltage VCC = 2 V 1.5 V
VCC = 4.5 V 3.15
VCC = 6 V 4.2
VIL Low-level input voltage VCC = 2 V 0.5 V
VCC = 4.5 V 1.35
VCC = 6 V 1.8
VI Input control voltage 0 VCC V
VIS Analog switch I/O voltage VEE VCC V
tt Input transition (rise and fall) time VCC = 2 V 0 1000 ns
VCC = 4.5 V 0 500
VCC = 6 V 0 400
TA Operating free-air temperature –55 125 °C
Cpd Power dissipation capacitance(3) 50 pF
(1) All unused inputs of the device must be held at VCC or GND to ensure proper device operation. Refer to the TI application report, Implications of Slow or Floating CMOS Inputs, SCBA004.
(2) In certain applications, the external load resistor current may include both VCC and signal-line components. To avoid drawing VCC current when switch current flows into the transmission gate inputs, the voltage drop across the bidirectional switch must not exceed 0.6 V (calculated from ron values shown in Electrical Characteristics table). No VCC current flows through RL if the switch current flows into the COM OUT/IN A terminal.
(3) Cpd is used to determine the dynamic power consumption, per package.
PD = Cpd VCC2 fI + Σ (CL + CS) VCC2 fO
fO = output frequency
fI = input frequency
CL = output load capacitance
CS = switch capacitance
VCC = supply voltage

6.4 Thermal Information

THERMAL METRIC(1) CD74HC4051-EP UNIT
D (SOIC)
16 PINS
RθJA Junction-to-ambient thermal resistance 81.7 °C/W
RθJC(top) Junction-to-case (top) thermal resistance 43.1
RθJB Junction-to-board thermal resistance 39.2
ψJT Junction-to-top characterization parameter 10.7
ψJB Junction-to-board characterization parameter 38.9
(1) For more information about traditional and new thermal metrics, see the IC Package Thermal Metrics application report, SPRA953.

6.5 Electrical Characteristics

over operating free-air temperature range (unless otherwise noted)
PARAMETER TEST CONDITIONS VEE VCC TA = 25°C TA = –55°C to 125°C UNIT
MIN TYP MAX MIN TYP MAX
ron IO = 1 mA, VI = VIH or VIL,
See Figure 1
VIS = VCC or VEE 0 V 4.5 V 70 160 240 Ω
0 V 6 V 60 140 210
–4.5 V 4.5 V 40 120 180
VIS = VCC to VEE 0 V 4.5 V 90 180 270
0 V 6 V 80 160 240
–4.5 V 4.5 V 45 130 195
∆ron Between any two channels 0 V 4.5 V 10 Ω
0 V 6 V 8.5
–4.5 V 4.5 V 5
IIZ For switch OFF:
When VIS = VCC, VOS = VEE;
When VIS = VEE, VOS = VCC
For switch ON:
All applicable combinations of VIS and VOS voltage levels,
VI = VIH or VIL
0 V 6 V ±0.2 ±2 µA
–5 V 5 V ±0.4 ±4
IIL VI = VCC or GND 0 V 6 V ±0.1 ±1 µA
ICC IO = 0, VI = VCC or GND When VIS = VEE, VOS = VCC 0 V 6 V 8 160 µA
When VIS = VCC, VOS = VEE –5 V 5 V 16 320

6.6 Analog Channel Characteristics

TA = 25°C
PARAMETER TEST CONDITIONS VEE VCC MIN TYP MAX UNIT
CI Switch input capacitance 5 pF
CCOM Common output capacitance 25 pF
fmax Minimum switch frequency response at –3 dB See Figure 6, Figure 2, and (1)(2) –2.25 V 2.25 V 145 MHz
–4.5 V 4.5 V 180
Sine-wave distortion See Figure 7 –2.25 V 2.25 V 0.03%
–4.5 V 4.5 V 0.018%
Switch OFF signal feedthrough See Figure 8, Figure 3 and (2)(3) –2.25 V 2.25 V –73 dB
–4.5 V 4.5 V –75
(1) Adjust input voltage to obtain 0 dBm at VOS for fIN = 1 MHz.
(2) VIS is centered at (VCC – VEE)/2.
(3) Adjust input for 0 dBm

6.7 Switching Characteristics

over recommended operating free-air temperature range (unless otherwise noted) (see Figure 9)
PARAMETER FROM
(INPUT)
TO
(OUTPUT)
LOAD
CAPACITANCE
VEE VCC TA = 25°C TA = –55°C TO 125°C UNIT
MIN TYP MAX MIN TYP MAX
tpd IN OUT CL = 15 pF 5 V 4 ns
CL = 50 pF 0 V 2 V 60 90
4.5 V 12 18
6 V 10 15
–4.5 V 4.5 V 8 12
CL = 15 pF 5 V 19 ns
ten ADDRESS SEL or E OUT CL = 50 pF 0 V 2 V 225 340
4.5 V 45 68
6 V 38 57
–4.5 V 4.5 V 32 48
tdis ADDRESS SEL or E OUT CL = 15 pF 5 V 19 ns
CL = 50 pF 0 V 2 V 225 340
4.5 V 45 68
6 V 38 57
–4.5 V 4.5 V 32 48
CI Control CL = 50 pF 10 10 pF

6.8 Typical Characteristics

typical_ON_resistance__scls464.gif
Figure 1. Typical ON-Resistance vs Input Signal Voltage
channel_OFF_feed_through_scls464.gif
Figure 3. Channel Off Feedthrough
channel_ON_bandwidth__scls464.gif
Figure 2. Channel On Bandwidth

6.8.1 Recommended Operating Area as a Function of Supply Voltages

rec_op_1_scls464.gif
Figure 4. Supply Operating Region
rec_op_2_scls464.gif
Figure 5. Supply Operating Region