JAJSU74B December   2003  – April 2024 CD74HC4051-Q1

PRODUCTION DATA  

  1.   1
  2. 特長
  3. アプリケーション
  4. 概要
  5. Pin Configuration and Functions
  6. Specifications
    1. 5.1 Absolute Maximum Ratings
    2. 5.2 Recommended Operating Conditions
    3. 5.3 Recommended Operating Area as a Function of Supply Voltages
    4. 5.4 Electrical Characteristics
    5. 5.5 Switching Characteristics
    6. 5.6 Operating Characteristics
    7. 5.7 Analog Channel Characteristics
    8. 5.8 Typical Characteristics
  7. Parameter Measurement Information
  8. Detailed Description
    1. 7.1 Functional Block Diagram
    2. 7.2 Device Functional Modes
  9. Device and Documentation Support
    1. 8.1 ドキュメントの更新通知を受け取る方法
    2. 8.2 サポート・リソース
    3. 8.3 Trademarks
    4. 8.4 静電気放電に関する注意事項
    5. 8.5 用語集
  10. Revision History
  11. 10Mechanical, Packaging, and Orderable Information

パッケージ・オプション

デバイスごとのパッケージ図は、PDF版データシートをご参照ください。

メカニカル・データ(パッケージ|ピン)
  • PW|16
  • D|16
サーマルパッド・メカニカル・データ
発注情報

Absolute Maximum Ratings

over operating free-air temperature range (unless otherwise noted) (1)
MINMAXUNIT
VCC − VEE (see (2))Supply voltage range−0.510.5V
VCCSupply voltage range−0.57V
VEESupply voltage range+0.5−7V
IIK (VI < −0.5V or VI > VCC + 0.5V)Input clamp current±20mA
IOK (VO < VEE − 0.5V or VO > VCC + 0.5V)Output clamp current±20mA
(VI > VEE − 0.5V or VI < VCC + 0.5V)Switch current±25mA
Continuous current through VCC or GND±50mA
IEEVEE current−20mA

RθJA

Package thermal impedance

D package

91.6°C/W

PW package

116.5°C/W
TJMaximum junction temperature150°C
Lead temperature (during soldering):At distance 1/16 ± 1/32 inch (1,59 ± 0,79 mm) from case for 10 s max300°C
TstgStorage temperature range−65150°C
Stresses beyond those listed under Absolute Maximum Ratings may cause permanent damage to the device. These are stress ratings only, and functional operation of the device at these or any other conditions beyond those indicated under Recommended Operating Conditions is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
All voltages referenced to GND unless otherwise specified.