JAJSF38F May 2014 – March 2018 DRV2604L
PRODUCTION DATA.
To configure the DRV2604L device in ERM open-loop operation, the ERM must be selected by writing the N_ERM_LRA bit to 0 (in register 0x1A), and the ERM_OPEN_LOOP bit to 1 in register 0x1D.