JAJSPK9 January   2023 DRV2901

PRODUCTION DATA  

  1. 特長
  2. アプリケーション
  3. 概要
  4. Revision History
  5. Pin Configuration and Functions
  6. Specifications
    1. 6.1 Absolute Maximum Ratings
    2. 6.2 ESD Ratings
    3. 6.3 Recommended Operating Conditions
    4. 6.4 Thermal Information
    5. 6.5 Electrical Characteristics
    6. 6.6 Typical Characteristics
  7. Detailed Description
    1. 7.1 Block Diagrams
    2. 7.2 Feature Description
      1. 7.2.1 Error Reporting
      2. 7.2.2 Device Reset
      3. 7.2.3 Device Protection System
        1. 7.2.3.1 Overcurrent (OC) Protection With Current Limiting and Overload Detection
        2. 7.2.3.2 Overtemperature Protection
        3. 7.2.3.3 Undervoltage Protection (UVP) and Power-On Reset (POR)
  8. Applications and Implementation
    1. 8.1 Application Information
    2. 8.2 Typical Application
  9. Power Supply Recommendations
    1. 9.1 System Power-up/power-down Sequence
      1. 9.1.1 Powering Up
      2. 9.1.2 Powering Down
    2. 9.2 System Design Recommendations
      1. 9.2.1 VDD Pin
      2. 9.2.2 VREG Pin
      3. 9.2.3 OTW Pin
  10. 10Mechanical, Packaging, and Orderable Information

パッケージ・オプション

メカニカル・データ(パッケージ|ピン)
サーマルパッド・メカニカル・データ
発注情報

Absolute Maximum Ratings

over operating free-air temperature range unless otherwise noted (1)
VDD to AGND–0.3 V to 13.2 V
GVDD_X to AGND–0.3 V to 13.2 V
PVDD_X to GND_X (2)–0.3 V to 71 V
OUT_X to GND_X (2)–0.3 V to 71V
BST_X to GND_X (2)–0.3 V to 79.7 V
VREG to AGND–0.3 V to 4.2 V
GND_X to GND–0.3 V to 0.3 V
GND_X to AGND–0.3 V to 0.3 V
GND to AGND–0.3 V to 0.3 V
PWM_X, OC_ADJ, M1, M2, M3 to AGND–0.3 V to 4.2 V
RESET_X, SD, OTW to AGND–0.3 V to 7 V
Maximum continuous sink current ( SD, OTW)9 mA
Maximum operating junction temperature range, TJ0°C to 125°C
Storage temperature–40°C to 125°C
Lead temperature, 1,6 mm (1/16 inch) from case for 10 seconds260°C
Minimum pulse duration, low50 ns
Stresses beyond those listed under Absolute Maximum Ratings may cause permanent damage to the device. These are stress ratings only, and functional operation of the device at these or any other conditions beyond those indicated under Recommended Operating Conditions is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
These voltages represent the dc voltage + peak ac waveform measured at the terminal of the device in all conditions.