JAJSJS9A july 2023 – july 2023 DRV8262
PRODUCTION DATA
FAULT | CONDITION | ERROR REPORT | H-BRIDGE | CHARGE PUMP | LOGIC | RECOVERY |
---|---|---|---|---|---|---|
VM undervoltage (UVLO) | VM < VUVLO | nFAULT | Disabled | Disabled | Reset | VM > VUVLO |
VCP undervoltage (CPUV) | VCP < VCPUV | nFAULT | Disabled | Operating | Operating | VCP > VCPUV |
Logic Supply POR | VCC < VCCUVLO |
- |
Disabled | Disabled |
Reset |
VCC > VCCUVLO |
Overcurrent (OCP) | IOUT > IOCP, OCPM = 0 | nFAULT | Disabled | Operating | Operating | Latched: nSLEEP reset pulse |
IOUT > IOCP, OCPM = 1 |
nFAULT |
Disabled |
Operating |
Operating |
Automatic retry: tRETRY | |
Thermal Shutdown (OTSD) | TJ > TTSD, OCPM = 0 | nFAULT | Disabled | Disabled | Operating | Latched: nSLEEP reset pulse |
TJ > TTSD, OCPM = 1 | nFAULT |
Disabled |
Disabled |
Operating |
Automatic: TJ < TOTSD - THYS_OTSD |