SLVSAB9E May   2010  – November 2015 DRV8814

PRODUCTION DATA.  

  1. Features
  2. Applications
  3. Description
  4. Revision History
  5. Pin Configuration and Functions
  6. Specifications
    1. 6.1 Absolute Maximum Ratings
    2. 6.2 ESD Ratings
    3. 6.3 Recommended Operating Conditions
    4. 6.4 Thermal Information
    5. 6.5 Electrical Characteristics
    6. 6.6 Typical Characteristics
  7. Detailed Description
    1. 7.1 Overview
    2. 7.2 Functional Block Diagram
    3. 7.3 Feature Description
      1. 7.3.1 PWM Motor Drivers
    4. 7.4 Device Functional Modes
      1. 7.4.1 Bridge Control
      2. 7.4.2 Current Regulation
      3. 7.4.3 Decay Mode and Braking
      4. 7.4.4 Blanking Time
      5. 7.4.5 nRESET and nSLEEP Operation
      6. 7.4.6 Protection Circuits
        1. 7.4.6.1 Overcurrent Protection (OCP)
        2. 7.4.6.2 Thermal Shutdown (TSD)
        3. 7.4.6.3 Undervoltage Lockout (UVLO)
  8. Application and Implementation
    1. 8.1 Application Information
    2. 8.2 Typical Application
      1. 8.2.1 Design Requirements
      2. 8.2.2 Detailed Design Procedure
        1. 8.2.2.1 Current Regulation
        2. 8.2.2.2 Decay Modes
        3. 8.2.2.3 Sense Resistor
      3. 8.2.3 Application Curves
  9. Power Supply Recommendations
    1. 9.1 Bulk Capacitance
    2. 9.2 Power Supply and Logic Sequencing
  10. 10Layout
    1. 10.1 Layout Guidelines
    2. 10.2 Layout Example
    3. 10.3 Thermal Considerations
      1. 10.3.1 Thermal Protection
      2. 10.3.2 Power Dissipation
      3. 10.3.3 Heatsinking
  11. 11Device and Documentation Support
    1. 11.1 Documentation Support
      1. 11.1.1 Related Documentation
    2. 11.2 Community Resources
    3. 11.3 Trademarks
    4. 11.4 Electrostatic Discharge Caution
    5. 11.5 Glossary
  12. 12Mechanical, Packaging, and Orderable Information

パッケージ・オプション

メカニカル・データ(パッケージ|ピン)
サーマルパッド・メカニカル・データ

5 Pin Configuration and Functions

PWP Package
28-Pin HTSSOP with PowerPAD™
Top View
DRV8814 po_lvs997.gif

Pin Functions

PIN I/O(1) DESCRIPTION EXTERNAL COMPONENTS
OR CONNECTIONS
NAME NO.
POWER AND GROUND
GND 14, 28 - Device ground
VMA 4 - Bridge A power supply Connect to motor supply (8 V to 45 V). Both pins must be connected to the same supply, bypassed with a 0.1-µF capacitor to GND, and connected to appropriate bulk capacitance.
VMB 11 - Bridge B power supply
V3P3OUT 15 O 3.3-V regulator output Bypass to GND with a 0.47-μF 6.3-V ceramic capacitor. Can be used to supply VREF.
CP1 1 IO Charge pump flying capacitor Connect a 0.01-μF 50-V capacitor between CP1 and CP2.
CP2 2 IO Charge pump flying capacitor
VCP 3 IO High-side gate drive voltage Connect a 0.1-μF 16-V ceramic capacitor and a 1-MΩ to VM.
CONTROL
AENBL 21 I Bridge A enable Logic high to enable bridge A
APHASE 20 I Bridge A phase (direction) Logic high sets AOUT1 high, AOUT2 low
AI0 24 I Bridge A current set Sets bridge A current: 00 = 100%, 01 = 71%, 10 = 38%, 11 = 0
AI1 25 I
BENBL 22 I Bridge B enable Logic high to enable bridge B
BPHASE 23 I Bridge B phase (direction) Logic high sets BOUT1 high, BOUT2 low
BI0 26 I Bridge B current set Sets bridge B current: 00 = 100%, 01 = 71%, 10 = 38%, 11 = 0
BI1 27 I
DECAY 19 I Decay (brake) mode Low = brake (slow decay), high = coast (fast decay)
nRESET 16 I Reset input Active-low reset input initializes internal logic and disables the H-bridge outputs
nSLEEP 17 I Sleep mode input Logic high to enable device, logic low to enter low-power sleep mode
AVREF 12 I Bridge A current set reference input Reference voltage for winding current set. Can be driven individually with an external DAC for microstepping, or tied to a reference (e.g., V3P3OUT).
BVREF 13 I Bridge B current set reference input
STATUS
nFAULT 18 OD Fault Logic low when in fault condition (overtemp, overcurrent)
OUTPUT
ISENA 6 IO Bridge A ground / Isense Connect to current sense resistor for bridge A
ISENB 9 IO Bridge B ground / Isense Connect to current sense resistor for bridge B
AOUT1 5 O Bridge A output 1 Connect to motor winding A
AOUT2 7 O Bridge A output 2
BOUT1 10 O Bridge B output 1 Connect to motor winding B
BOUT2 8 O Bridge B output 2
(1) Directions: I = input, O = output, OZ = tri-state output, OD = open-drain output, IO = input/output