JAJSM96 may 2023 DRV8849
PRODUCTION DATA
In this mode, after an OTSD event, all the outputs are disabled and the nFAULT pins are driven low. Normal operation resumes (motor-driver operation and the nFAULT lines released) when the junction temperature falls below the overtemperature threshold limit minus the hysteresis (TOTSD – THYS_OTSD).