Follow these general guidelines when designing the power supply:
- The power supply should be designed to provide the recommended
operating conditions outlined in Section 5 in terms of DC voltage, AC noise, and start-up ramp time.
- The maximum current draw for the DS280DF810 is provided in
Section 5 . This figure can be used to calculate the maximum current the supply
must provide. Typical mission-mode current draw can be inferred from the typical
power consumption in Section 5.
- The DS280DF810 does not require any special power supply
filtering (that is, ferrite bead) provided the recommended operating conditions
are met. Only standard supply decoupling is required. Refer to Section 4 for details concerning the recommended supply decoupling.