10 Power Supply Recommendations
TI recommends connecting the supply (VCC) and ground (GND) pins to power planes that are routed on adjacent layers of the PCB. Additionally, careful attention should be paid to bypassing the supply using a capacitor. A 0.1-µF bypass capacitor should be connected to the VCC pin such that the capacitor is as close as possible to the device.