JAJSJQ2C june   2021  – march 2023 HDC3020-Q1 , HDC3021-Q1 , HDC3022-Q1

PRODUCTION DATA  

  1. 特長
  2. アプリケーション
  3. 概要
  4. Revision History
  5. Device Comparison
  6. Pin Configuration and Functions
  7. Specifications
    1. 7.1 Absolute Maximum Ratings
    2. 7.2 ESD Ratings
    3. 7.3 Recommended Operating Conditions
    4. 7.4 Thermal Information
    5. 7.5 Electrical Characteristics
    6. 7.6 I2C Interface Timing
    7. 7.7 Timing Diagram
    8. 7.8 Typical Characteristics
  8. Detailed Description
    1. 8.1 Overview
    2. 8.2 Functional Block Diagram
    3. 8.3 Feature Description
      1. 8.3.1  Factory Installed Polyimide Tape
      2. 8.3.2  Factory Installed IP67 Protection Cover
      3. 8.3.3  Wettable Flanks
      4. 8.3.4  Measurement of Relative Humidity and Temperature
      5. 8.3.5  Offset Error Correction: Accuracy Restoration
      6. 8.3.6  NIST Traceability of Relative Humidity and Temperature Sensor
      7. 8.3.7  Measurement Modes: Trigger-On Demand vs Auto Measurement
      8. 8.3.8  Heater
      9. 8.3.9  ALERT Output With Programmable Interrupts
      10. 8.3.10 Checksum Calculation
      11. 8.3.11 Programmable Offset of Relative Humidity and Temperature Results
    4. 8.4 Device Functional Modes
      1. 8.4.1 Sleep Mode vs Measurement Mode
    5. 8.5 Programming
      1. 8.5.1 I2C Interface
      2. 8.5.2 I2C Serial Bus Address Configuration
      3. 8.5.3 I2C Write - Send Device Command
      4. 8.5.4 I2C Read - Retrieve Single Data Result
      5. 8.5.5 I2C Read - Retrieve Multi Data Result
      6. 8.5.6 I2C Repeated START - Send Command and Retrieve Data Results
      7. 8.5.7 Command Table and Detailed Description
        1. 8.5.7.1 Reset
          1. 8.5.7.1.1 Soft Reset
          2. 8.5.7.1.2 I2C General Call Reset
        2. 8.5.7.2 Trigger-On Demand
        3. 8.5.7.3 Auto Measurement Mode
          1. 8.5.7.3.1 Auto Measurement Mode: Enable and Configure Measurement Interval
          2. 8.5.7.3.2 Auto Measurement Mode: Measurement Readout
          3. 8.5.7.3.3 Auto Measurement Mode: Exit
          4. 8.5.7.3.4 Auto Measurement Mode: Measurement History Readout
          5. 8.5.7.3.5 Override Default Device Power-On and Device-Reset State
        4. 8.5.7.4 ALERT Output Configuration
          1. 8.5.7.4.1 ALERT Output: Environmental Tracking of Temperature and Relative Humidity
          2. 8.5.7.4.2 ALERT Output: Representation of Environmental Thresholds and Default Threshold Values
          3. 8.5.7.4.3 ALERT Output: Steps to Calculate and Program Environmental Thresholds
          4. 8.5.7.4.4 ALERT Output: Deactivation of Environmental Tracking
          5. 8.5.7.4.5 ALERT Output: Transfer Thresholds into Non-Volatile Memory
        5. 8.5.7.5 Programmable Measurement Offset
          1. 8.5.7.5.1 Representation of Offset Value and Factory Shipped Default Value
          2. 8.5.7.5.2 Factory Shipped Default Offset Values
          3. 8.5.7.5.3 Calculate Relative Humidity Offset Value
          4. 8.5.7.5.4 Calculate Temperature Offset Value
          5. 8.5.7.5.5 Write an Offset Value
          6. 8.5.7.5.6 Verify a Programmed Offset Value
        6. 8.5.7.6 Status Register
        7. 8.5.7.7 Heater: Enable and Disable
        8. 8.5.7.8 Heater: Configure Level of Heater Current
        9. 8.5.7.9 Read NIST ID/Serial Number
  9. Application and Implementation
    1. 9.1 Application Information
    2. 9.2 Typical Application
      1. 9.2.1 Design Requirements
      2. 9.2.2 Detailed Design Procedure
      3. 9.2.3 Application Curve
    3. 9.3 Power Supply Recommendations
    4. 9.4 Layout
      1. 9.4.1 Layout Guidelines
      2. 9.4.2 Layout Example
      3. 9.4.3 Storage and PCB Assembly
        1. 9.4.3.1 Storage and Handling
        2. 9.4.3.2 Soldering Reflow
        3. 9.4.3.3 Rework
        4. 9.4.3.4 Exposure to High Temperature and High Humidity Conditions
        5. 9.4.3.5 Bake/Rehydration Procedure
  10. 10Device and Documentation Support
    1. 10.1 Documentation Support
      1. 10.1.1 Related Documentation
    2. 10.2 ドキュメントの更新通知を受け取る方法
    3. 10.3 サポート・リソース
    4. 10.4 Trademarks
    5. 10.5 静電気放電に関する注意事項
    6. 10.6 用語集
  11. 11Mechanical, Packaging, and Orderable Information

パッケージ・オプション

デバイスごとのパッケージ図は、PDF版データシートをご参照ください。

メカニカル・データ(パッケージ|ピン)
  • DEF|8
サーマルパッド・メカニカル・データ
発注情報

I2C Read - Retrieve Single Data Result

An I2C read sequence is performed to retrieve data from the HDC302x-Q1. The I2C read sequence must follow the I2C write sequence that was used to initiate the data acquisition. A CRC byte always accompanies data that is transmitted by the HDC302x-Q1. If the I2C controller does not use the CRC byte to perform a data integrity check, then an I2C NACK can be issued to discard CRC transmission and save time. Both of these I2C read scenarios are illustrated in Figure 8-5 and Figure 8-6.

GUID-18E72CA1-4AA6-4261-A540-83B9B2A44017-low.gifFigure 8-5 I2C Read Single Data Result, CRC Discarded
GUID-16E75A1B-C8B7-4CA5-A1F6-2DF783A02CEF-low.gifFigure 8-6 I2C Read Single Data Result, CRC Retained

The HDC302x-Q1 will stop transmission of a data byte if the I2C controller fails to ACK after any byte of data.