JAJSJQ2C june   2021  – march 2023 HDC3020-Q1 , HDC3021-Q1 , HDC3022-Q1

PRODUCTION DATA  

  1. 特長
  2. アプリケーション
  3. 概要
  4. Revision History
  5. Device Comparison
  6. Pin Configuration and Functions
  7. Specifications
    1. 7.1 Absolute Maximum Ratings
    2. 7.2 ESD Ratings
    3. 7.3 Recommended Operating Conditions
    4. 7.4 Thermal Information
    5. 7.5 Electrical Characteristics
    6. 7.6 I2C Interface Timing
    7. 7.7 Timing Diagram
    8. 7.8 Typical Characteristics
  8. Detailed Description
    1. 8.1 Overview
    2. 8.2 Functional Block Diagram
    3. 8.3 Feature Description
      1. 8.3.1  Factory Installed Polyimide Tape
      2. 8.3.2  Factory Installed IP67 Protection Cover
      3. 8.3.3  Wettable Flanks
      4. 8.3.4  Measurement of Relative Humidity and Temperature
      5. 8.3.5  Offset Error Correction: Accuracy Restoration
      6. 8.3.6  NIST Traceability of Relative Humidity and Temperature Sensor
      7. 8.3.7  Measurement Modes: Trigger-On Demand vs Auto Measurement
      8. 8.3.8  Heater
      9. 8.3.9  ALERT Output With Programmable Interrupts
      10. 8.3.10 Checksum Calculation
      11. 8.3.11 Programmable Offset of Relative Humidity and Temperature Results
    4. 8.4 Device Functional Modes
      1. 8.4.1 Sleep Mode vs Measurement Mode
    5. 8.5 Programming
      1. 8.5.1 I2C Interface
      2. 8.5.2 I2C Serial Bus Address Configuration
      3. 8.5.3 I2C Write - Send Device Command
      4. 8.5.4 I2C Read - Retrieve Single Data Result
      5. 8.5.5 I2C Read - Retrieve Multi Data Result
      6. 8.5.6 I2C Repeated START - Send Command and Retrieve Data Results
      7. 8.5.7 Command Table and Detailed Description
        1. 8.5.7.1 Reset
          1. 8.5.7.1.1 Soft Reset
          2. 8.5.7.1.2 I2C General Call Reset
        2. 8.5.7.2 Trigger-On Demand
        3. 8.5.7.3 Auto Measurement Mode
          1. 8.5.7.3.1 Auto Measurement Mode: Enable and Configure Measurement Interval
          2. 8.5.7.3.2 Auto Measurement Mode: Measurement Readout
          3. 8.5.7.3.3 Auto Measurement Mode: Exit
          4. 8.5.7.3.4 Auto Measurement Mode: Measurement History Readout
          5. 8.5.7.3.5 Override Default Device Power-On and Device-Reset State
        4. 8.5.7.4 ALERT Output Configuration
          1. 8.5.7.4.1 ALERT Output: Environmental Tracking of Temperature and Relative Humidity
          2. 8.5.7.4.2 ALERT Output: Representation of Environmental Thresholds and Default Threshold Values
          3. 8.5.7.4.3 ALERT Output: Steps to Calculate and Program Environmental Thresholds
          4. 8.5.7.4.4 ALERT Output: Deactivation of Environmental Tracking
          5. 8.5.7.4.5 ALERT Output: Transfer Thresholds into Non-Volatile Memory
        5. 8.5.7.5 Programmable Measurement Offset
          1. 8.5.7.5.1 Representation of Offset Value and Factory Shipped Default Value
          2. 8.5.7.5.2 Factory Shipped Default Offset Values
          3. 8.5.7.5.3 Calculate Relative Humidity Offset Value
          4. 8.5.7.5.4 Calculate Temperature Offset Value
          5. 8.5.7.5.5 Write an Offset Value
          6. 8.5.7.5.6 Verify a Programmed Offset Value
        6. 8.5.7.6 Status Register
        7. 8.5.7.7 Heater: Enable and Disable
        8. 8.5.7.8 Heater: Configure Level of Heater Current
        9. 8.5.7.9 Read NIST ID/Serial Number
  9. Application and Implementation
    1. 9.1 Application Information
    2. 9.2 Typical Application
      1. 9.2.1 Design Requirements
      2. 9.2.2 Detailed Design Procedure
      3. 9.2.3 Application Curve
    3. 9.3 Power Supply Recommendations
    4. 9.4 Layout
      1. 9.4.1 Layout Guidelines
      2. 9.4.2 Layout Example
      3. 9.4.3 Storage and PCB Assembly
        1. 9.4.3.1 Storage and Handling
        2. 9.4.3.2 Soldering Reflow
        3. 9.4.3.3 Rework
        4. 9.4.3.4 Exposure to High Temperature and High Humidity Conditions
        5. 9.4.3.5 Bake/Rehydration Procedure
  10. 10Device and Documentation Support
    1. 10.1 Documentation Support
      1. 10.1.1 Related Documentation
    2. 10.2 ドキュメントの更新通知を受け取る方法
    3. 10.3 サポート・リソース
    4. 10.4 Trademarks
    5. 10.5 静電気放電に関する注意事項
    6. 10.6 用語集
  11. 11Mechanical, Packaging, and Orderable Information

パッケージ・オプション

デバイスごとのパッケージ図は、PDF版データシートをご参照ください。

メカニカル・データ(パッケージ|ピン)
  • DEF|8
サーマルパッド・メカニカル・データ
発注情報

Measurement Modes: Trigger-On Demand vs Auto Measurement

Two types of measurement modes are available on the HDC302x-Q1: Trigger-on Demand and Auto Measurement mode.

Trigger-on Demand is a single measurement reading of temperature and relative humidity that is triggered through an I2C command on an as-needed basis. After the measurement is converted, the device remains in sleep mode until another I2C command is received.

Auto Measurement mode is a recurring measurement reading of temperature and relative humidity, eliminating the need to repeatedly initiate a measurement request through an I2C command. The measurement interval can be adjusted from 1 measurement every 2 seconds to 10 measurements every second. In Auto Measurement mode, the HDC302x-Q1 wakes up from sleep to measurement mode based on the selected sampling rate.

Auto Measurement mode helps to reduce overall system power consumption in two ways. First, by removing the need to repeatedly initiate a measurement through an I2C command, sink current through the SCL and SDA pullup resistors is eliminated. Secondly, a microcontroller can be programmed into a deep sleep mode, and only woken up through an interrupt by the ALERT pin in the event of excessive temperature and relative humidity measurements.