JAJSCM3E August 2006 – January 2021 INA193A-Q1 , INA194A-Q1 , INA195A-Q1 , INA196A-Q1 , INA197A-Q1 , INA198A-Q1
PRODUCTION DATA
Vsupply is set to 12 V, Vref at 2.5 V and a 10-mΩ shunt. The accuracy of the current will typically be less than 0.5% for current greater than ±2 A. For current lower than ±2 A, the accuracy will vary; use GUID-B3025330-FFB0-4BC1-A65C-BAAE9201B41C.html#GUID-B3025330-FFB0-4BC1-A65C-BAAE9201B41C for accuracy considerations.