JAJSLN1 June   2022 ISO7041-Q1

PRODUCTION DATA  

  1. 特長
  2. アプリケーション
  3. 説明
  4. Revision History
    1.     Device Comparison Table
  5. Pin Configuration and Functions
  6. Specifications
    1. 6.1  絶対最大定格
    2. 6.2  ESD Ratings
    3. 6.3  Recommended Operating Conditions
    4. 6.4  Thermal Information
    5. 6.5  Power Ratings
    6.     Insulation Specifications
    7. 6.6  Safety-Related Certifications
    8. 6.7  Safety Limiting Values
    9. 6.8  Electrical Characteristics 5V Supply
    10. 6.9  Supply Current Characteristics 5V Supply
    11. 6.10 Electrical Characteristics 3.3V Supply
    12. 6.11 Supply Current Characteristics 3.3V Supply
    13. 6.12 Switching Characteristics
    14. 6.13 Insulation Characteristics Curves
    15. 6.14 Typical Characteristics
  7. Parameter Measurement Information
  8. Detailed Description
    1. 8.1 Overview
    2. 8.2 Functional Block Diagram
    3. 8.3 Feature Description
      1. 8.3.1 Refresh
      2. 8.3.2 Electromagnetic Compatibility (EMC) Considerations
    4. 8.4 Device Functional Modes
      1. 8.4.1 Device I/O Schematics
  9. Application and Implementation
    1. 9.1 Application Information
      1. 9.1.1 Insulation Lifetime
    2. 9.2 Typical Application
      1. 9.2.1 Design Requirements
      2. 9.2.2 Detailed Design Procedure
      3. 9.2.3 Application Curves
  10. 10Power Supply Recommendations
  11. 11Layout
    1. 11.1 Layout Guidelines
      1. 11.1.1 PCB Material
    2. 11.2 Layout Example
  12. 12Device and Documentation Support
    1. 12.1 Documentation Support
      1. 12.1.1 Related Documentation
    2. 12.2 Receiving Notification of Documentation Updates
    3. 12.3 サポート・リソース
    4. 12.4 Trademarks
    5. 12.5 Electrostatic Discharge Caution
    6. 12.6 Glossary
  13. 13Mechanical, Packaging, and Orderable Information

パッケージ・オプション

メカニカル・データ(パッケージ|ピン)
サーマルパッド・メカニカル・データ
発注情報

Safety-Related Certifications

VDE CSA UL CQC TUV
Certified according to DIN VDE V 0884-11:2017- 01 Certified according to IEC 60950-1 and IEC 62368-1 Certified according to UL 1577 Component Recognition Program Certified according to GB4943.1-2011 Certified according to EN 61010-1:2010/A1:2019, EN 60950- 1:2006/A2:2013 and EN 62368-1:2014
Maximum transient isolation voltage,
4242 VPK;
Maximum repetitive peak isolation voltage, 566 VPK;
Maximum surge isolation voltage,
4000 VPK
3000 VRMS insulation per CSA 60950-1-07+A1+A2, IEC 60950-1 2nd Ed.+A1+A2, CSA 62368-1- 14 and IEC 62368-1:2014 370 VRMS (DBQ-16) maximum working voltage (pollution degree 2, material group I)
 
Single protection,
3000 VRMS
Basic insulation, Altitude ≤ 5000 m, Tropical Climate,
400 VRMS maximum working voltage
EN 61010- 1:2010/A1:2019, 300 VRMS basic isolation
EN 60950- 1:2006/A2:2013 and EN 62368-1:2014, 400 VRMS basic isolation
Certification Planned Certification Planned Certification Planned Certification Planned Certification Planned