JAJSJM0B
june 2021 – april 2023
JFE150
PRODUCTION DATA
1
1
特長
2
アプリケーション
3
概要
4
Revision History
5
Pin Configuration and Functions
6
Specifications
6.1
Absolute Maximum Ratings
6.2
ESD Ratings
6.3
Recommended Operating Conditions
6.4
Thermal Information
6.5
Electrical Characteristics
6.6
Typical Characteristics
7
Parameter Measurement Information
7.1
AC Measurement Configurations
8
Detailed Description
8.1
Overview
8.2
Functional Block Diagram
8.3
Feature Description
8.3.1
Ultra-Low Noise
8.3.2
Low Gate Current
8.3.3
Input Protection
8.4
Device Functional Modes
9
Application and Implementation
9.1
Application Information
9.1.1
Input Protection Diodes
9.1.2
Capacitive Transducer Input Stage
9.1.3
Common-Source Amplifier
9.1.4
Composite Amplifiers
9.2
Typical Application
9.2.1
Design Requirements
9.2.2
Detailed Design Procedure
9.2.3
Application Curves
9.3
Power Supply Recommendations
9.4
Layout
9.4.1
Layout Guidelines
9.4.2
Layout Example
10
Device and Documentation Support
10.1
Device Support
10.1.1
Development Support
10.1.1.1
PSpice® for TI
10.1.1.2
TINA-TI™シミュレーション・ソフトウェア (無償ダウンロード)
10.1.1.3
TI のリファレンス・デザイン
10.1.1.4
フィルタ設計ツール
10.2
Documentation Support
10.2.1
Related Documentation
10.3
ドキュメントの更新通知を受け取る方法
10.4
サポート・リソース
10.5
Trademarks
10.6
静電気放電に関する注意事項
10.7
用語集
11
Mechanical, Packaging, and Orderable Information
パッケージ・オプション
メカニカル・データ(パッケージ|ピン)
DCK|5
MPDS025J
DBV|5
MPDS018T
サーマルパッド・メカニカル・データ
発注情報
jajsjm0b_oa
jajsjm0b_pm
6.2
ESD Ratings
VALUE
UNIT
V
(ESD)
Electrostatic discharge
Human body model (HBM), per ANSI/ESDA/JEDEC JS-001
(1)
±2500
V
Charged device model (CDM), per ANSI/ESDA/JEDEC JS-002
(2)
±500
(1)
JEDEC document JEP155 states that 500-V HBM allows safe manufacturing with a standard ESD control process.
(2)
JEDEC document JEP157 states that 250-V CDM allows safe manufacturing with a standard ESD control process.