Table 8-5 Output Capacitors for Fixed Output Voltage
Application—Surface MountOUTPUT VOLTAGE (V)(1)(2) | INDUCTANCE (µH) | SURFACE MOUNT |
---|
AVX TPS SERIES | SPRAGUE 594D SERIES | KEMET T495 SERIES |
---|
NO. | C CODE | NO. | C CODE | NO. | C CODE |
---|
3.3 | 10 | 4 | C2 | 3 | C1 | 4 | C4 |
15 | 4 | C2 | 3 | C1 | 4 | C4 |
22 | 3 | C2 | 2 | C7 | 3 | C4 |
33 | 2 | C2 | 2 | C6 | 2 | C4 |
5 | 10 | 4 | C2 | 4 | C6 | 4 | C4 |
15 | 3 | C2 | 2 | C7 | 3 | C4 |
22 | 3 | C2 | 2 | C7 | 3 | C4 |
33 | 2 | C2 | 2 | C3 | 2 | C4 |
47 | 2 | C2 | 1 | C7 | 2 | C4 |
12 | 10 | 4 | C5 | 3 | C6 | 5 | C9 |
15 | 3 | C5 | 2 | C7 | 4 | C8 |
22 | 2 | C5 | 2 | C6 | 3 | C8 |
33 | 2 | C5 | 1 | C7 | 2 | C8 |
47 | 2 | C4 | 1 | C6 | 2 | C8 |
68 | 1 | C5 | 1 | C5 | 2 | C7 |
100 | 1 | C4 | 1 | C5 | 1 | C8 |
(1) No. represents the number of identical capacitor types to be connected in parallel
(2) C Code indicates the Capacitor Reference number in
Table 8-1 and
Table 8-2 for identifying the specific component from the manufacturer.
Table 8-6 Output Capacitors for Fixed Output Voltage
Application—Through HoleOUTPUT VOLTAGE (V)(1)(2) | INDUCTANCE (µH) | THROUGH HOLE |
---|
SANYO OS-CON SA SERIES | SANYO MV-GX SERIES | NICHICON PL SERIES | PANASONIC HFQ SERIES |
---|
NO. | C CODE | NO. | C CODE | NO. | C CODE | NO. | C CODE |
---|
3.3 | 10 | 1 | C3 | 1 | C10 | 1 | C6 | 2 | C6 |
15 | 1 | C3 | 1 | C10 | 1 | C6 | 2 | C5 |
22 | 1 | C5 | 1 | C10 | 1 | C5 | 1 | C7 |
33 | 1 | C2 | 1 | C10 | 1 | C13 | 1 | C5 |
5 | 10 | 2 | C4 | 1 | C10 | 1 | C6 | 2 | C5 |
15 | 1 | C5 | 1 | C10 | 1 | C5 | 1 | C6 |
22 | 1 | C5 | 1 | C5 | 1 | C5 | 1 | C5 |
33 | 1 | C4 | 1 | C5 | 1 | C13 | 1 | C5 |
47 | 1 | C4 | 1 | C4 | 1 | C13 | 2 | C3 |
12 | 10 | 2 | C7 | 1 | C5 | 1 | C18 | 2 | C5 |
15 | 1 | C8 | 1 | C5 | 1 | C17 | 1 | C5 |
22 | 1 | C7 | 1 | C5 | 1 | C13 | 1 | C5 |
33 | 1 | C7 | 1 | C3 | 1 | C11 | 1 | C4 |
47 | 1 | C7 | 1 | C3 | 1 | C10 | 1 | C3 |
68 | 1 | C7 | 1 | C2 | 1 | C10 | 1 | C3 |
100 | 1 | C7 | 1 | C2 | 1 | C9 | 1 | C1 |
(1) No. represents the number of identical capacitor types to be connected in parallel
(2) C Code indicates the Capacitor Reference number in
Table 8-1 and
Table 8-2 for identifying the specific component from the manufacturer.
Table 8-7 Input Capacitors for Fixed Output Voltage
Application—Surface MountOUTPUT VOLTAGE (V)(1)(2)(3) | INDUCTANCE (µH) | SURFACE MOUNT |
---|
AVX TPS SERIES | SPRAGUE 594D SERIES | KEMET T495 SERIES |
---|
NO. | C CODE | NO. | C CODE | NO. | C CODE |
---|
3.3 | 10 | 2 | C5 | 1 | C7 | 2 | C8 |
15 | 3 | C9 | 1 | C10 | 3 | C10 |
22 | See(4) | See(4) | 2 | C13 | 3 | C12 |
33 | See(4) | See(4) | 2 | C13 | 2 | C12 |
5 | 10 | 2 | C5 | 1 | C7 | 2 | C8 |
15 | 2 | C5 | 1 | C7 | 2 | C8 |
22 | 3 | C10 | 2 | C12 | 3 | C11 |
33 | See(4) | See(4) | 2 | C13 | 3 | C12 |
47 | See(4) | See(4) | 1 | C13 | 2 | C12 |
12 | 10 | 2 | C7 | 2 | C10 | 2 | C7 |
15 | 2 | C7 | 2 | C10 | 2 | C7 |
22 | 3 | C10 | 2 | C12 | 3 | C10 |
33 | 3 | C10 | 2 | C12 | 3 | C10 |
47 | See(4) | See(4) | 2 | C13 | 3 | C12 |
68 | See(4) | See(4) | 2 | C13 | 2 | C12 |
100 | See(4) | See(4) | 1 | C13 | 2 | C12 |
(1) Assumes worst case maximum input voltage and load current for a given inductance value
(2) No. represents the number of identical capacitor types to be connected in parallel
(3) C Code indicates the Capacitor Reference number in
Table 8-1 and
Table 8-2 for identifying the specific component from the manufacturer.
(4) Check voltage rating of capacitors to be greater than application input voltage.
Table 8-8 Input Capacitors for Fixed Output Voltage
Application—Through HoleOUTPUT VOLTAGE (V)(1)(2)(3) | INDUCTANCE (µH) | THROUGH HOLE |
---|
SANYO OS-CON SA SERIES | SANYO MV-GX SERIES | NICHICON PL SERIES | PANASONIC HFQ SERIES |
---|
NO. | C CODE | NO. | C CODE | NO. | C CODE | NO. | C CODE |
---|
3.3 | 10 | 1 | C7 | 2 | C4 | 1 | C5 | 1 | C6 |
15 | 1 | C10 | 1 | C10 | 1 | C18 | 1 | C6 |
22 | See(4) | See(4) | 1 | C14 | 1 | C24 | 1 | C13 |
33 | See(4) | See(4) | 1 | C12 | 1 | C20 | 1 | C12 |
5 | 10 | 1 | C7 | 2 | C4 | 1 | C14 | 1 | C6 |
15 | 1 | C7 | 2 | C4 | 1 | C14 | 1 | C6 |
22 | See(4) | See(4) | 1 | C10 | 1 | C18 | 1 | C13 |
33 | See(4) | See(4) | 1 | C14 | 1 | C23 | 1 | C13 |
47 | See(4) | See(4) | 1 | C12 | 1 | C20 | 1 | C12 |
12 | 10 | 1 | C9 | 1 | C10 | 1 | C18 | 1 | C6 |
15 | 1 | C10 | 1 | C10 | 1 | C18 | 1 | C6 |
22 | 1 | C10 | 1 | C10 | 1 | C18 | 1 | C6 |
33 | See(4) | See(4) | 1 | C10 | 1 | C18 | 1 | C6 |
47 | See(4) | See(4) | 1 | C13 | 1 | C23 | 1 | C13 |
68 | See(4) | See(4) | 1 | C12 | 1 | C21 | 1 | C12 |
100 | See(4) | See(4) | 1 | C11 | 1 | C22 | 1 | C11 |
(1) Assumes worst case maximum input voltage and load current for a given inductance value
(2) No. represents the number of identical capacitor types to be connected in parallel
(3) C Code indicates the Capacitor Reference number in
Table 8-1 and
Table 8-2 for identifying the specific component from the manufacturer.
(4) Check voltage rating of capacitors to be greater than application input voltage.