A battery monitor function is enabled when CH1 is configured as a buck, and at least one of the EN pins is greater than VEN or VCC_HOLD is greater than VSYNC. If BMIN_PRG is less than BMIN_PRG threshold (VSLEEP) and BMIN_FIX is greater than BMIN_FIX threshold (VBMIN_FIX), BMOUT is connected to AGND. BMOUT opens when BMIN_FIX is greater than VBMIN_FIX or BMIN_PRG is greater than VSLEEP. By using a resistor voltage divider at BMIN_PRG, the threshold of the battery monitor can be programmed, but the resistor divider and the internal 30-μA hysteresis current (ISLEEP1) will drain the battery.
To adjust the low battery voltage detection levels, select the battery monitor resistor values as follows. The low battery falling detection level should be lower than 5.7 V and the low battery rising detection level should be higher than 6.0 V to program.