7.7 Serial Parallel Interface (SPI) Bus Interface AC Timing Specifications(1)(2)
Over operating free-air temperature range (unless otherwise noted)
PARAMETER |
TEST CONDITIONS |
MIN |
TYP |
MAX |
UNIT |
f SCK |
SCK frequency |
MODE_SEL = 1 |
|
10 |
20 |
MHz |
TSCK |
SCK period |
|
50 |
|
|
ns |
tPH |
SCK pulse width high |
|
|
0.4 × TSCK |
|
ns |
tPL |
SCK pulse width low |
|
0.4 × TSCK |
|
ns |
tSU |
MOSI setup time |
|
4 |
4 |
|
ns |
tH |
MOSI hold time |
4 |
4 |
|
ns |
tSSSu |
SS_N setup time |
|
14 |
18 |
|
ns |
tSSH |
SS_N hold time |
4 |
4 |
|
ns |
tSSOF |
SS_N off time |
|
1 |
|
μs |
tODZ |
MISO driven to TRI-STATE time |
|
|
20 |
|
ns |
tOZD |
MISO TRI-STATE-to-Driven time |
|
|
10 |
|
ns |
tOD |
MISO output delay time |
|
|
15 |
|
ns |
(1) Typical values are parametric norms at VDD = 2.5 V, TA = 25ºC, and recommended operating conditions at the time of product characterization. Typical values are not production tested.
(2) These specifications support SPI 1.0 specifications.