JAJSQW3A September 2024 – October 2024 LOG300
PRODUCTION DATA
デバイスごとのパッケージ図は、PDF版データシートをご参照ください。
PARAMETER | TEST CONDITIONS | MIN | TYP | MAX | UNIT | ||
---|---|---|---|---|---|---|---|
AFE AC PERFORMANCE | |||||||
LCE | Log conformance error | f = 1MHz | ±1 | dB | |||
TA = –40°C to +125°C | ±1 | ||||||
DR | Dynamic range | For LCE = ±1dB, f = 1MHz | 91 | dB | |||
Log Detector slope variation(1) | Ref_Res = open | ±4.5 | % | ||||
Ref_Res = 56kΩ | ±1 | ±7 | |||||
Ref_Res = 56kΩ | TA = –40°C to +125°C | ±7.2 | |||||
AFE INPUT | |||||||
AFE input | Typical input voltage | LCE = ±1dB, f = 1MHz | 7µ | 200m | VP | ||
TA = –40°C to +125°C | 8µ | 200m | |||||
LCE = ±2dB, f = 20MHz | 12µ | 200m | |||||
TA = –40°C to +125°C | 14µ | 200m | |||||
Output rise time | BPF = 180kHz, CF = 350pF | 35 | µs | ||||
BPF = 1MHz, CF = 500pF | 50 | ||||||
Output fall time | BPF = 180kHz, CF = 350pF | 65 | µs | ||||
BPF = 1MHz, CF = 500pF | 45 | ||||||
LOG_OUT | |||||||
Minimum output voltage(1) | LNA_In = 10nF to AGND | 290 | 335 | mV | |||
TA = –40°C to +125°C | 436 | ||||||
POWER SUPPLY | |||||||
VCC Quiescent current | Total AFE, LNA_Out = open | 6 | 7.2 | mA | |||
TA = –40°C to +125°C | 8.3 | ||||||
POWER DOWN | |||||||
VCC Disabled current | Total AFE, VCC = 3.3V | TA = –40°C to +125°C | 65 | µA | |||
Total AFE, VCC = 5V | 130 | ||||||
AFE_ En |
AFE enable voltage threshold | VCC– 1.2 | V | ||||
AFE disable voltage threshold | AGND + 0.6 | V |