JAJSST7A January 2024 – May 2024 MCF8315C-Q1
PRODUCTION DATA
The buck overcurrent event is sensed by monitoring the current flowing through high-side MOSFET of the buck regulator. If the current through the high-side MOSFET exceeds the IBK_OCP threshold for a time longer than the deglitch time, a buck OCP event is recognized and the buck regulator MOSFETs are disabled (Hi-Z). MCF8315C-Q1 goes into reset state whenever buck OCP event occurs, since the internal circuitry in MCF8315C-Q1 is powered from the buck regulator output.