SLFS023H April 1978 – December 2024 NA556 , NE556 , SA556 , SE556
PRODUCTION DATA
デバイスごとのパッケージ図は、PDF版データシートをご参照ください。
Table 6-1 shows the device truth table. For a valid reset voltage condition, use an external pullup resistor to VCC (if using the RESET functionality), or short the RESET pin directly to VCC (if the RESET functionality is not used).
RESET VOLTAGE(1) | TRIGGER VOLTAGE(1) | THRESHOLD VOLTAGE(1) | OUTPUT | DISCHARGE SWITCH |
---|---|---|---|---|
LOW | Irrelevant | Irrelevant | Low | On |
> MAX | < 1/3 VCC | Irrelevant(2) | High | Off |
> MAX | > 1/3 VCC | > 2/3 VCC | Low | On |
> MAX | > 1/3 VCC | < 2/3 VCC | As previously established |