JAJSGK7C December   2018  – September 2020 SN74AXCH1T45

PRODUCTION DATA  

  1. 特長
  2. アプリケーション
  3. 概要
  4. Revision History
  5. Pin Configuration and Functions
  6. Specifications
    1. 6.1 Absolute Maximum Ratings
    2. 6.2 ESD Ratings
    3. 6.3 Recommended Operating Conditions
    4. 6.4 Thermal Information
    5. 6.5 Electrical Characteristics
    6. 6.6 Operating Characteristics: TA = 25°C
    7. 6.7 Typical Characteristics
  7. Parameter Measurement Information
    1. 7.1 Load Circuit and Voltage Waveforms
  8. Detailed Description
    1. 8.1 Overview
    2. 8.2 Functional Block Diagram
    3. 8.3 Feature Description
      1. 8.3.1 Standard CMOS Inputs
      2. 8.3.2 Balanced High-Drive CMOS Push-Pull Outputs
      3. 8.3.3 Partial Power Down (Ioff)
      4. 8.3.4 VCC Isolation
      5. 8.3.5 Over-voltage Tolerant Inputs
      6. 8.3.6 Negative Clamping Diodes
      7. 8.3.7 Fully Configurable Dual-Rail Design
      8. 8.3.8 Supports High-Speed Translation
      9. 8.3.9 Bus-Hold Data Inputs
    4. 8.4 Device Functional Modes
  9. Application and Implementation
    1. 9.1 Application Information
      1. 9.1.1 Enable Times
    2. 9.2 Typical Applications
      1. 9.2.1 Interrupt Request Application
        1. 9.2.1.1 Design Requirements
        2. 9.2.1.2 Detailed Design Procedure
        3. 9.2.1.3 Application Curve
      2. 9.2.2 Universal Asynchronous Receiver-Transmitter (UART) Interface Application
        1. 9.2.2.1 Design Requirements
        2. 9.2.2.2 Detailed Design Procedure
  10. 10Power Supply Recommendations
  11. 11Layout
    1. 11.1 Layout Guidelines
    2. 11.2 Layout Example
  12. 12Device and Documentation Support
    1. 12.1 Documentation Support
    2. 12.2 Receiving Notification of Documentation Updates
    3. 12.3 Support Resources
    4. 12.4 Trademarks
    5. 12.5 静電気放電に関する注意事項
    6. 12.6 Glossary
  13. 13Mechanical, Packaging, and Orderable Information

パッケージ・オプション

メカニカル・データ(パッケージ|ピン)
サーマルパッド・メカニカル・データ
発注情報

Electrical Characteristics

over operating free-air temperature range (unless otherwise noted) (1) (2)
PARAMETERTEST CONDITIONSVCCAVCCBOperating free-air temperature (TA)UNIT
–40°C to 85°C –40°C to 125°C
MINTYP(3)MAXMINTYPMAX
VOHHigh-level output voltageVI = VIHIOH = –100 µA0.7 V - 3.6 V0.7 V - 3.6 VVCCO – 0.1VCCO – 0.1V
IOH = –50 µA0.65 V0.65 V0.550.55
IOH = –200 µA0.76 V0.76 V0.580.58
IOH = –500 µA0.85 V0.85 V0.650.65
IOH = –3 mA1.1 V1.1 V0.850.85
IOH = –6 mA1.4 V1.4 V1.051.05
IOH = –8 mA1.65 V1.65 V1.21.2
IOH = –9 mA2.3 V2.3 V1.751.75
IOH = –12 mA3 V3 V2.32.3
VOLLow-level output voltageVI = VILIOL = 100 µA0.7 V - 3.6 V0.7 V - 3.6 V0.10.1V
IOL = 50 µA0.65 V0.65 V0.10.1
IOL = 200 µA0.76 V0.76 V0.180.18
IOL = 500 µA0.85 V0.85 V0.20.2
IOL = 3 mA1.1 V1.1 V0.250.25
IOL = 6 mA1.4 V1.4 V0.350.35
IOL = 8 mA1.65 V1.65 V0.450.45
IOL = 9 mA2.3 V2.3 V0.550.55
IOL = 12 mA3 V3 V0.70.7
IBHLBus-hold low sustaining current (4)VI = 0.20 V0.65 V0.65 V44µA
VI = 0.23 V0.76 V0.76 V87
VI = 0.26 V0.85 V0.85 V1010
VI = 0.39 V1.1 V1.1 V2020
VI = 0.49 V1.4 V1.4 V4030
VI = 0.58 V1.65 V1.65 V5545
VI = 0.7 V2.3 V2.3 V9080
VI = 0.8 V3 V3 V145135
IBHHBus-hold high sustaining current (5)VI = 0.45 V0.65 V0.65 V–4–4µA
VI = 0.53 V0.76 V0.76 V–8–7
VI = 0.59 V0.85 V0.85 V–10–10
VI = 0.71 V1.1 V1.1 V–20–20
VI = 0.91 V1.4 V1.4 V–40–30
VI = 1.07 V1.65 V1.65 V–55–45
VI = 1.6 V2.3 V2.3 V–90–80
VI = 2.0 V3 V3 V–145–135
IBHLOBus-hold low overdrive current (6)VI = 0 to VCC0.75 V0.75 V4040µA
0.84 V0.84 V5050
0.95 V0.95 V6565
1.3 V1.3 V105105
1.6 V1.6 V150150
1.95 V1.95 V205205
2.7 V2.7 V335335
3.6 V3.6 V480480
IBHHOBus-hold high overdrive current (7)VI = 0 to VCC0.75 V0.75 V–40–40µA
0.84 V0.84 V–50–50
0.95 V0.95 V–65–65
1.3 V1.3 V–105–105
1.6 V1.6 V–150–150
1.95 V1.95 V–205–205
2.7 V2.7 V–335–335
3.6 V3.6 V–480–480
IIInput leakage currentControl input (DIR): VI = VCCA or GND0.65 V - 3.6 V0.65 V - 3.6 V–0.50.5–11µA
A or B Port: Vi = VCCI or GND0.65 V - 3.6 V0.65 V - 3.6 V–44–88
IoffPartial power down currentA or B Port: Vi or Vo = 0 V - 3.6 V0 V0 V - 3.6 V–88–1212µA
0 V - 3.6 V0 V–88–1212
ICCAVCCA supply currentV= VCCI or GNDI= 00.65 V - 3.6 V0.65 V - 3.6 V812µA
0 V3.6 V–2–8
3.6 V0 V28
ICCBVCCB supply currentV= VCCI or GNDI= 00.65 V - 3.6 V0.65 V - 3.6 V812µA
0 V3.6 V28
3.6 V0 V–2–8
ICCA + ICCBCombined supply currentV= VCCI or GNDI= 00.65 V - 3.6 V0.65 V - 3.6 V1016µA
CiControl input capacitanceVI = 3.3 V or GND3.3 V3.3 V4.34.3pF
CioData I/O capacitance, A PortVO = 1.65 V DC +1 MHz -16 dBm sine wave3.3 V0 V7.47.4pF
CioData I/O capacitance, B PortVO = 1.65 V DC +1 MHz -16 dBm sine wave0 V3.3 V7.47.4pF
VCCI is the VCC associated with the input port.
VCCO is the VCC associated with the output port.
All typical data is taken at 25°C.
The bus-hold circuit can sink at least the minimum low sustaining current at VIL(MAX). IBHL should be measured after lowering VI to GND and then raising it to VIL(MAX).
The bus-hold circuit can source at least the minimum high sustaining current at VIH(MIN). IBHH should be measured after raising VI to VCC and then lowering it to VIH(MIN).
An external driver must source at least IBHLO to switch this node from low to high.
An external driver must sink at least IBHHO to switch this node from high to low.
Table 6-1 Switching Characteristics, VCCA = 0.7 V
PARAMETER FROM TO Test Conditions B-Port Supply Voltage (VCCB) UNIT
0.7 ± 0.05 V 0.8 ± 0.04 V 0.9 ± 0.045 V 1.2 ± 0.1 V 1.5 ± 0.1 V 1.8 ± 0.15 V 2.5 ± 0.2 V 3.3 ± 0.3 V
MIN MAX MIN MAX MIN MAX MIN MAX MIN MAX MIN MAX MIN MAX MIN MAX
tpd Propagation delay A B –40°C to 85°C 0.5 181 0.5 119 0.5 85 0.5 51 0.5 49 0.5 52 0.5 65 0.5 152 ns
–40°C to 125°C 0.5 181 0.5 119 0.5 85 0.5 51 0.5 49 0.5 52 0.5 65 0.5 152
B A –40°C to 85°C 0.5 181 0.5 162 0.5 136 0.5 96 0.5 91 0.5 89 0.5 88 0.5 88
–40°C to 125°C 0.5 181 0.5 162 0.5 136 0.5 96 0.5 91 0.5 89 0.5 88 0.5 88
tdis Disable time DIR A –40°C to 85°C 0.5 152 0.5 152 0.5 152 0.5 152 0.5 152 0.5 152 0.5 152 0.5 152 ns
–40°C to 125°C 0.5 152 0.5 152 0.5 152 0.5 152 0.5 152 0.5 152 0.5 152 0.5 152
DIR B –40°C to 85°C 0.5 170 0.5 127 0.5 102 0.5 48 0.5 42 0.5 46 0.5 58 0.5 108
–40°C to 125°C 0.5 170 0.5 127 0.5 102 0.5 48 0.5 42 0.5 46 0.5 58 0.5 108
ten Enable time DIR A –40°C to 85°C 0.5 343 0.5 278 0.5 231 0.5 141 0.5 132 0.5 134 0.5 144 0.5 193 ns
–40°C to 125°C 0.5 343 0.5 278 0.5 231 0.5 141 0.5 132 0.5 134 0.5 144 0.5 193
DIR B –40°C to 85°C 0.5 326 0.5 257 0.5 222 0.5 194 0.5 191 0.5 191 0.5 197 0.5 277
–40°C to 125°C 0.5 326 0.5 257 0.5 222 0.5 194 0.5 191 0.5 191 0.5 197 0.5 277
Table 6-2 Switching Characteristics, VCCA = 0.8 V
PARAMETER FROM TO Test Conditions B-Port Supply Voltage (VCCB) UNIT
0.7 ± 0.05 V 0.8 ± 0.04 V 0.9 ± 0.045 V 1.2 ± 0.1 V 1.5 ± 0.1 V 1.8 ± 0.15 V 2.5 ± 0.2 V 3.3 ± 0.3 V
MIN MAX MIN MAX MIN MAX MIN MAX MIN MAX MIN MAX MIN MAX MIN MAX
tpd Propagation delay A B –40°C to 85°C 0.5 162 0.5 98 0.5 65 0.5 33 0.5 28 0.5 26 0.5 27 0.5 37 ns
–40°C to 125°C 0.5 162 0.5 98 0.5 65 0.5 33 0.5 28 0.5 26 0.5 27 0.5 37
B A –40°C to 85°C 0.5 119 0.5 98 0.5 81 0.5 54 0.5 45 0.5 44 0.5 43 0.5 42
–40°C to 125°C 0.5 119 0.5 98 0.5 81 0.5 54 0.5 45 0.5 44 0.5 43 0.5 42
tdis Disable time DIR A –40°C to 85°C 0.5 107 0.5 107 0.5 107 0.5 107 0.5 107 0.5 107 0.5 107 0.5 107 ns
–40°C to 125°C 0.5 107 0.5 107 0.5 107 0.5 107 0.5 107 0.5 107 0.5 107 0.5 107
DIR B –40°C to 85°C 0.5 160 0.5 117 0.5 90 0.5 39 0.5 31 0.5 29 0.5 29 0.5 37
–40°C to 125°C 0.5 160 0.5 117 0.5 90 0.5 39 0.5 31 0.5 29 0.5 29 0.5 37
ten Enable time DIR A –40°C to 85°C 0.5 268 0.5 205 0.5 165 0.5 90 0.5 74 0.5 71 0.5 70 0.5 77 ns
–40°C to 125°C 0.5 268 0.5 205 0.5 165 0.5 90 0.5 74 0.5 71 0.5 70 0.5 77
DIR B –40°C to 85°C 0.5 257 0.5 194 0.5 161 0.5 130 0.5 125 0.5 126 0.5 125 0.5 132
–40°C to 125°C 0.5 257 0.5 194 0.5 161 0.5 130 0.5 125 0.5 126 0.5 125 0.5 132
Table 6-3 Switching Characteristics, VCCA = 0.9 V
PARAMETER FROM TO Test Conditions B-Port Supply Voltage (VCCB) UNIT
0.7 ± 0.05 V 0.8 ± 0.04 V 0.9 ± 0.045 V 1.2 ± 0.1 V 1.5 ± 0.1 V 1.8 ± 0.15 V 2.5 ± 0.2 V 3.3 ± 0.3 V
MIN MAX MIN MAX MIN MAX MIN MAX MIN MAX MIN MAX MIN MAX MIN MAX
tpd Propagation delay A B –40°C to 85°C 0.5 135 0.5 81 0.5 54 0.5 24 0.5 18 0.5 17 0.5 15 0.5 18 ns
–40°C to 125°C 0.5 135 0.5 81 0.5 54 0.5 24 0.5 18 0.5 17 0.5 15 0.5 18
B A –40°C to 85°C 0.5 86 0.5 65 0.5 54 0.5 41 0.5 30 0.5 26 0.5 23 0.5 23
–40°C to 125°C 0.5 86 0.5 65 0.5 54 0.5 41 0.5 30 0.5 26 0.5 23 0.5 23
tdis Disable time DIR A –40°C to 85°C 0.5 79 0.5 79 0.5 79 0.5 79 0.5 79 0.5 79 0.5 79 0.5 79 ns
–40°C to 125°C 0.5 79 0.5 79 0.5 79 0.5 79 0.5 79 0.5 79 0.5 79 0.5 79
DIR B –40°C to 85°C 0.5 154 0.5 111 0.5 85 0.5 34 0.5 27 0.5 25 0.5 21 0.5 23
–40°C to 125°C 0.5 154 0.5 111 0.5 85 0.5 34 0.5 27 0.5 25 0.5 21 0.5 23
ten Enable time DIR A –40°C to 85°C 0.5 227 0.5 166 0.5 131 0.5 71 0.5 53 0.5 48 0.5 42 0.5 44 ns
–40°C to 125°C 0.5 227 0.5 166 0.5 131 0.5 71 0.5 53 0.5 48 0.5 42 0.5 44
DIR B –40°C to 85°C 0.5 206 0.5 152 0.5 125 0.5 96 0.5 91 0.5 89 0.5 89 0.5 92
–40°C to 125°C 0.5 206 0.5 152 0.5 125 0.5 96 0.5 91 0.5 89 0.5 89 0.5 92
Table 6-4 Switching Characteristics, VCCA = 1.2 V
PARAMETER FROM TO Test Conditions B-Port Supply Voltage (VCCB) UNIT
0.7 ± 0.05 V 0.8 ± 0.04 V 0.9 ± 0.045 V 1.2 ± 0.1 V 1.5 ± 0.1 V 1.8 ± 0.15 V 2.5 ± 0.2 V 3.3 ± 0.3 V
MIN MAX MIN MAX MIN MAX MIN MAX MIN MAX MIN MAX MIN MAX MIN MAX
tpd Propagation delay A B –40°C to 85°C 0.5 95 0.5 54 0.5 41 0.5 16 0.5 11 0.5 9 0.5 8 0.5 8 ns
–40°C to 125°C 0.5 95 0.5 54 0.5 41 0.5 16 0.5 11 0.5 9 0.5 8 0.5 8
B A –40°C to 85°C 0.5 51 0.5 33 0.5 24 0.5 16 0.5 13 0.5 11 0.5 8 0.5 8
–40°C to 125°C 0.5 51 0.5 33 0.5 24 0.5 16 0.5 13 0.5 11 0.5 8 0.5 8
tdis Disable time DIR A –40°C to 85°C 0.5 28 0.5 28 0.5 28 0.5 28 0.5 28 0.5 28 0.5 28 0.5 28 ns
–40°C to 125°C 0.5 28 0.5 28 0.5 28 0.5 28 0.5 28 0.5 28 0.5 28 0.5 28
DIR B –40°C to 85°C 0.5 148 0.5 105 0.5 78 0.5 30 0.5 23 0.5 20 0.5 16 0.5 16
–40°C to 125°C 0.5 148 0.5 105 0.5 78 0.5 30 0.5 23 0.5 20 0.5 16 0.5 16
ten Enable time DIR A –40°C to 85°C 0.5 191 0.5 129 0.5 96 0.5 43 0.5 34 0.5 30 0.5 23 0.5 22 ns
–40°C to 125°C 0.5 191 0.5 129 0.5 96 0.5 43 0.5 34 0.5 30 0.5 23 0.5 22
DIR B –40°C to 85°C 0.5 116 0.5 75 0.5 61 0.5 41 0.5 37 0.5 36 0.5 35 0.5 35
–40°C to 125°C 0.5 116 0.5 75 0.5 61 0.5 41 0.5 37 0.5 36 0.5 35 0.5 35
Table 6-5 Switching Characteristics, VCCA = 1.5 V
PARAMETER FROM TO Test Conditions B-Port Supply Voltage (VCCB) UNIT
0.7 ± 0.05 V 0.8 ± 0.04 V 0.9 ± 0.045 V 1.2 ± 0.1 V 1.5 ± 0.1 V 1.8 ± 0.15 V 2.5 ± 0.2 V 3.3 ± 0.3 V
MIN MAX MIN MAX MIN MAX MIN MAX MIN MAX MIN MAX MIN MAX MIN MAX
tpd Propagation delay A B –40°C to 85°C 0.5 91 0.5 45 0.5 30 0.5 13 0.5 9 0.5 8 0.5 6 0.5 6 ns
–40°C to 125°C 0.5 91 0.5 45 0.5 30 0.5 13 0.5 9 0.5 8 0.5 6 0.5 6
B A –40°C to 85°C 0.5 49 0.5 28 0.5 18 0.5 11 0.5 9 0.5 8 0.5 6 0.5 5
–40°C to 125°C 0.5 49 0.5 28 0.5 18 0.5 11 0.5 9 0.5 8 0.5 6 0.5 5
tdis Disable time DIR A –40°C to 85°C 0.5 20 0.5 20 0.5 20 0.5 20 0.5 20 0.5 20 0.5 20 0.5 20 ns
–40°C to 125°C 0.5 20 0.5 20 0.5 20 0.5 20 0.5 20 0.5 20 0.5 20 0.5 20
DIR B –40°C to 85°C 0.5 146 0.5 103 0.5 76 0.5 28 0.5 21 0.5 19 0.5 15 0.5 14
–40°C to 125°C 0.5 146 0.5 103 0.5 76 0.5 28 0.5 21 0.5 19 0.5 15 0.5 14
ten Enable time DIR A –40°C to 85°C 0.5 186 0.5 124 0.5 89 0.5 38 0.5 29 0.5 26 0.5 20 0.5 18 ns
–40°C to 125°C 0.5 186 0.5 124 0.5 89 0.5 38 0.5 29 0.5 26 0.5 20 0.5 18
DIR B –40°C to 85°C 0.5 104 0.5 58 0.5 43 0.5 31 0.5 28 0.5 27 0.5 25 0.5 25
–40°C to 125°C 0.5 104 0.5 58 0.5 43 0.5 31 0.5 28 0.5 27 0.5 25 0.5 25
Table 6-6 Switching Characteristics, VCCA = 1.8 V
PARAMETER FROM TO Test Conditions B-Port Supply Voltage (VCCB) UNIT
0.7 ± 0.05 V 0.8 ± 0.04 V 0.9 ± 0.045 V 1.2 ± 0.1 V 1.5 ± 0.1 V 1.8 ± 0.15 V 2.5 ± 0.2 V 3.3 ± 0.3 V
MIN MAX MIN MAX MIN MAX MIN MAX MIN MAX MIN MAX MIN MAX MIN MAX
tpd Propagation delay A B –40°C to 85°C 0.5 89 0.5 44 0.5 26 0.5 11 0.5 8 0.5 7 0.5 6 0.5 5 ns
–40°C to 125°C 0.5 89 0.5 44 0.5 26 0.5 11 0.5 8 0.5 7 0.5 6 0.5 5
B A –40°C to 85°C 0.5 52 0.5 26 0.5 17 0.5 9 0.5 8 0.5 7 0.5 6 0.5 5
–40°C to 125°C 0.5 52 0.5 26 0.5 17 0.5 9 0.5 8 0.5 7 0.5 6 0.5 5
tdis Disable time DIR A –40°C to 85°C 0.5 17 0.5 17 0.5 17 0.5 17 0.5 17 0.5 17 0.5 17 0.5 17 ns
–40°C to 125°C 0.5 17 0.5 17 0.5 17 0.5 17 0.5 17 0.5 17 0.5 17 0.5 17
DIR B –40°C to 85°C 0.5 147 0.5 103 0.5 76 0.5 27 0.5 20 0.5 18 0.5 14 0.5 13
–40°C to 125°C 0.5 147 0.5 103 0.5 76 0.5 27 0.5 20 0.5 18 0.5 14 0.5 13
ten Enable time DIR A –40°C to 85°C 0.5 185 0.5 122 0.5 86 0.5 35 0.5 27 0.5 24 0.5 19 0.5 17 ns
–40°C to 125°C 0.5 185 0.5 122 0.5 86 0.5 35 0.5 27 0.5 24 0.5 19 0.5 17
DIR B –40°C to 85°C 0.5 100 0.5 54 0.5 37 0.5 27 0.5 25 0.5 24 0.5 22 0.5 22
–40°C to 125°C 0.5 100 0.5 54 0.5 37 0.5 27 0.5 25 0.5 24 0.5 22 0.5 22
Table 6-7 Switching Characteristics, VCCA = 2.5 V
PARAMETER FROM TO Test Conditions B-Port Supply Voltage (VCCB) UNIT
0.7 ± 0.05 V 0.8 ± 0.04 V 0.9 ± 0.045 V 1.2 ± 0.1 V 1.5 ± 0.1 V 1.8 ± 0.15 V 2.5 ± 0.2 V 3.3 ± 0.3 V
MIN MAX MIN MAX MIN MAX MIN MAX MIN MAX MIN MAX MIN MAX MIN MAX
tpd Propagation delay A B –40°C to 85°C 0.5 88 0.5 42 0.5 23 0.5 8 0.5 6 0.5 6 0.5 5 0.5 5 ns
–40°C to 125°C 0.5 88 0.5 42 0.5 23 0.5 8 0.5 6 0.5 6 0.5 5 0.5 5
B A –40°C to 85°C 0.5 65 0.5 27 0.5 15 0.5 8 0.5 6 0.5 6 0.5 5 0.5 4
–40°C to 125°C 0.5 65 0.5 27 0.5 15 0.5 8 0.5 6 0.5 6 0.5 5 0.5 4
tdis Disable time DIR A –40°C to 85°C 0.5 13 0.5 13 0.5 13 0.5 13 0.5 13 0.5 13 0.5 13 0.5 13 ns
–40°C to 125°C 0.5 13 0.5 13 0.5 13 0.5 13 0.5 13 0.5 13 0.5 13 0.5 13
DIR B –40°C to 85°C 0.5 146 0.5 102 0.5 75 0.5 27 0.5 19 0.5 17 0.5 13 0.5 12
–40°C to 125°C 0.5 146 0.5 102 0.5 75 0.5 27 0.5 19 0.5 17 0.5 13 0.5 12
ten Enable time DIR A –40°C to 85°C 0.5 191 0.5 122 0.5 85 0.5 33 0.5 25 0.5 22 0.5 17 0.5 16 ns
–40°C to 125°C 0.5 191 0.5 122 0.5 85 0.5 33 0.5 25 0.5 22 0.5 17 0.5 16
DIR B –40°C to 85°C 0.5 95 0.5 50 0.5 31 0.5 20 0.5 18 0.5 17 0.5 17 0.5 17
–40°C to 125°C 0.5 95 0.5 50 0.5 31 0.5 20 0.5 18 0.5 17 0.5 17 0.5 17
Table 6-8 Switching Characteristics, VCCA = 3.3 V
PARAMETER FROM TO Test Conditions B-Port Supply Voltage (VCCB) UNIT
0.7 ± 0.05 V 0.8 ± 0.04 V 0.9 ± 0.045 V 1.2 ± 0.1 V 1.5 ± 0.1 V 1.8 ± 0.15 V 2.5 ± 0.2 V 3.3 ± 0.3 V
MIN MAX MIN MAX MIN MAX MIN MAX MIN MAX MIN MAX MIN MAX MIN MAX
tpd Propagation delay A B –40°C to 85°C 0.5 87 0.5 42 0.5 23 0.5 8 0.5 5 0.5 5 0.5 4 0.5 4 ns
–40°C to 125°C 0.5 87 0.5 42 0.5 23 0.5 8 0.5 5 0.5 5 0.5 4 0.5 4
B A –40°C to 85°C 0.5 154 0.5 37 0.5 18 0.5 8 0.5 6 0.5 5 0.5 5 0.5 4
–40°C to 125°C 0.5 154 0.5 37 0.5 18 0.5 8 0.5 6 0.5 5 0.5 5 0.5 4
tdis Disable time DIR A –40°C to 85°C 0.5 12 0.5 12 0.5 12 0.5 12 0.5 12 0.5 12 0.5 12 0.5 12 ns
–40°C to 125°C 0.5 12 0.5 12 0.5 12 0.5 12 0.5 12 0.5 12 0.5 12 0.5 12
DIR B –40°C to 85°C 0.5 147 0.5 102 0.5 75 0.5 26 0.5 19 0.5 17 0.5 13 0.5 12
–40°C to 125°C 0.5 147 0.5 102 0.5 75 0.5 26 0.5 19 0.5 17 0.5 13 0.5 12
ten Enable time DIR A –40°C to 85°C 0.5 275 0.5 129 0.5 88 0.5 34 0.5 24 0.5 21 0.5 17 0.5 16 ns
–40°C to 125°C 0.5 275 0.5 129 0.5 88 0.5 34 0.5 24 0.5 21 0.5 17 0.5 16
DIR B –40°C to 85°C 0.5 94 0.5 49 0.5 30 0.5 18 0.5 16 0.5 16 0.5 15 0.5 15
–40°C to 125°C 0.5 94 0.5 49 0.5 30 0.5 18 0.5 16 0.5 16 0.5 15 0.5 15