Follow these steps to use the Open Load Detection.
- Mute the input digital signal chain, set device's output driver into play mode. Register 0x03 = 0x0F.
- Configure and enable open load detection. Register 0x7B = 0x09; Register 0x79 =
0xC0.
- Wait 20 ms.
- Read back open load status from Register 0x7C. Open load result only valid when DONE bit is 1.
Note: Take Open Load Report of CH2 in PBTL mode.