SLOSE88 December   2024 TAS6754-Q1

ADVANCE INFORMATION  

  1.   1
  2. Features
  3. Applications
  4. Description
  5. Pin Configuration and Functions
  6. Specifications
    1. 5.1 Absolute Maximum Ratings
    2. 5.2 Recommended Operating Conditions
    3. 5.3 ESD Ratings
    4. 5.4 Thermal Information
    5. 5.5 Electrical Characteristics
    6. 5.6 Typical Characteristics
  7. Parameter Measurement Information
  8. Detailed Description
    1. 7.1 Overview
    2. 7.2 Functional Block Diagram
    3. 7.3 Feature Description
      1. 7.3.1 Power Supply
        1. 7.3.1.1 Power-Supply Sequence
          1. 7.3.1.1.1 Power-Up Sequence
          2. 7.3.1.1.2 Power-Down Sequence
        2. 7.3.1.2 Device Initialization and Power-On-Reset (POR)
      2. 7.3.2 Serial Audio Port
        1. 7.3.2.1 Left-Justified Timing
        2. 7.3.2.2 I2S Mode
        3. 7.3.2.3 DSP Mode
        4. 7.3.2.4 TDM Mode
        5. 7.3.2.5 SDOUT - Data Output
        6. 7.3.2.6 Device Clocking
          1. 7.3.2.6.1 Clock Rates
          2. 7.3.2.6.2 Clock Halt Auto-recovery
          3. 7.3.2.6.3 Sample Rate on the Fly Change
        7. 7.3.2.7 Clock Error Handling
      3. 7.3.3 Digital Audio Processing
        1. 7.3.3.1 PVDD Foldback
        2. 7.3.3.2 High-Pass Filter
        3. 7.3.3.3 Analog Gain
        4. 7.3.3.4 Digital Volume Control
          1. 7.3.3.4.1 Auto Mute
        5. 7.3.3.5 Gain Compensation Biquads
        6. 7.3.3.6 Low Latency Signal Path
        7. 7.3.3.7 Full Feature Low Latency Path
      4. 7.3.4 Class-D operation and Spread Spectrum Control
        1. 7.3.4.1 1L Modulation
        2. 7.3.4.2 High-Frequency Pulse-Width Modulator (PWM)
        3. 7.3.4.3 Spread Spectrum Control
        4. 7.3.4.4 Gate Drive
        5. 7.3.4.5 Power FETs
      5. 7.3.5 Load Diagnostics
        1. 7.3.5.1 DC Load Diagnostics
          1. 7.3.5.1.1 Automatic DC Load Diagnostics at Device Initialization
          2. 7.3.5.1.2 Automatic DC load diagnostics during Hi-Z or PLAY
          3. 7.3.5.1.3 Manual start of DC load diagnostics
          4. 7.3.5.1.4 Short-to-Ground
          5. 7.3.5.1.5 Short-to-Power
          6. 7.3.5.1.6 Shorted-Load and Open-Load
        2. 7.3.5.2 Line Output Diagnostics
        3. 7.3.5.3 AC Load Diagnostics
          1. 7.3.5.3.1 Operating Principal
          2. 7.3.5.3.2 Stimulus
          3. 7.3.5.3.3 Load Impedance
          4. 7.3.5.3.4 Tweeter Detection
        4. 7.3.5.4 Real-Time Load Diagnostics
        5. 7.3.5.5 DC Resistance Measurement
      6. 7.3.6 Protection and Monitoring
        1. 7.3.6.1 Overcurrent Limit (Cycle-By-Cycle)
        2. 7.3.6.2 Overcurrent Shutdown
        3. 7.3.6.3 Current Sense
        4. 7.3.6.4 DC Detect
        5. 7.3.6.5 Digital Clip Detect
        6. 7.3.6.6 Charge Pump
        7. 7.3.6.7 Temperature Protection and Monitoring
          1. 7.3.6.7.1 Overtemperature Shutdown
          2. 7.3.6.7.2 Overtemperature Warning
          3. 7.3.6.7.3 Thermal Gain Foldback
        8. 7.3.6.8 Power Failures
      7. 7.3.7 Hardware Control Pins
        1. 7.3.7.1 FAULT Pin
        2. 7.3.7.2 PD Pin
        3. 7.3.7.3 STBY Pin
        4. 7.3.7.4 GPIO Pins
          1. 7.3.7.4.1 General Purpose Input
          2. 7.3.7.4.2 General Purpose Output
        5. 7.3.7.5 Advanced GPIO functions
          1. 7.3.7.5.1 Clock Synchronization
            1. 7.3.7.5.1.1 External SYNC signal (GPIO sync)
            2. 7.3.7.5.1.2 Synchronization through the audio serial clock (SCLK)
            3. 7.3.7.5.1.3 TAS6754-Q1 as clock source for external devices
    4. 7.4 Device Functional Modes
      1. 7.4.1 Internal Reporting Signals
        1. 7.4.1.1 Fault Signal
        2. 7.4.1.2 Warning Signal
      2. 7.4.2 Device States and Flags
        1. 7.4.2.1 Audio Channel States
          1. 7.4.2.1.1 SHUTDOWN State
          2. 7.4.2.1.2 DEEP SLEEP State
          3. 7.4.2.1.3 LOAD DIAG State
          4. 7.4.2.1.4 SLEEP State
          5. 7.4.2.1.5 Hi-Z State
          6. 7.4.2.1.6 PLAY State
          7. 7.4.2.1.7 FAULT State
          8. 7.4.2.1.8 Auto Recovery (AUTOREC) State
        2. 7.4.2.2 Status and Memory Registers
      3. 7.4.3 Fault Events
        1. 7.4.3.1 Power Fault Events
          1. 7.4.3.1.1 DVDD Power-On-Reset (POR)
          2. 7.4.3.1.2 DVDD Undervoltage Fault
          3. 7.4.3.1.3 VBAT Undervoltage Fault
          4. 7.4.3.1.4 PVDD Overvoltage Fault
          5. 7.4.3.1.5 PVDD Undervoltage Fault
        2. 7.4.3.2 Overtemperature Shutdown (OTSD) Event
        3. 7.4.3.3 Overcurrent Limit Fault Event
        4. 7.4.3.4 Overcurrent Shutdown Event
        5. 7.4.3.5 DC Fault Event
        6. 7.4.3.6 Clock Error Event
        7. 7.4.3.7 Charge Pump Fault Event
      4. 7.4.4 Warning Events
        1. 7.4.4.1 Overtemperature Warning Event
        2. 7.4.4.2 Overcurrent Limit Warning Event
        3. 7.4.4.3 Clip Detect Warning Event
    5. 7.5 Programming
      1. 7.5.1 I2C Serial Communication Bus
      2. 7.5.2 I2C Address Selection
      3. 7.5.3 I2C Bus Protocol
      4. 7.5.4 Random Write
      5. 7.5.5 Sequential Write
      6. 7.5.6 Random Read
      7. 7.5.7 Sequential Read
  9. Application Information Disclaimer
    1. 8.1 Application Information
      1. 8.1.1 Reconstruction Filter Design
    2. 8.2 Typical Application
      1. 8.2.1 BTL Application
    3. 8.3 Power Supply Recommendations
    4. 8.4 Layout
      1. 8.4.1 Layout Guidelines
        1. 8.4.1.1 Electrical Connection of Thermal pad and Heat Sink
        2. 8.4.1.2 EMI Considerations
        3. 8.4.1.3 General Guidelines
      2. 8.4.2 Layout Example
      3. 8.4.3 Thermal Considerations
  10. Device and Documentation Support
    1. 9.1 Documentation Support
      1. 9.1.1 Related Documentation
    2. 9.2 Receiving Notification of Documentation Updates
    3. 9.3 Support Resources
    4. 9.4 Trademarks
    5. 9.5 Electrostatic Discharge Caution
    6. 9.6 Glossary
  11. 10Revision History
  12. 11Mechanical, Packaging, and Orderable Information

パッケージ・オプション

メカニカル・データ(パッケージ|ピン)
サーマルパッド・メカニカル・データ
発注情報
Load Impedance

The load impedance as seen by the device is simply the ratio of the voltage across the output pins and the current flowing through the load.

Typically the load has a frequency dependent magnitude and causes current and voltage to have a phase shift. The TAS6754-Q1 internally captures the load impedance as a complex value consisting of a real and imaginary part. Expressing a load impedance in magnitude and phase or in real and imaginary part is mathematically equivalent. Both forms can be transformed into each other without loss of information. After AC load diagnostics have finished, the real and imaginary parts of the complex impedance are available by channel for readout in I2C registers as shown in .