over operating free-air temperature range (unless otherwise noted)(1) | MIN | MAX | UNIT |
---|
VCC | Supply voltage | –0.5 | 7 | V |
VI | Input voltage(2) | –0.5 | 7 | V |
II | Input current | –20 | 20 | mA |
IO | Output current | –25 | | mA |
ICC | Supply current | –100 | 100 | mA |
Tstg | Storage temperature | –65 | 150 | °C |
TJ | Max Junction Temperature | VCC ≤ 3.6 V | | 130 | ℃ |
VCC ≤ 5.25V | | 90 | ℃ |
(1) Operation outside the Absolute Maximum Ratings may cause permanent
device damage. Absolute Maximum Ratings do not imply functional operation
of the device at these or any other conditions beyond those listed under
Recommended Operating Conditions. If used outside the Recommended
Operating Conditions but within the Absolute Maximum Ratings, the
device may not be fully functional, and this may affect device reliability,
functionality, performance, and shorten the device lifetime.
(2) The input negative-voltage and output voltage ratings may be exceeded if the input and output current ratings are observed.