JAJSL28E january   2021  – march 2023 TCAN1043A-Q1

PRODUCTION DATA  

  1. 特長
  2. アプリケーション
  3. 概要
  4. Revision History
  5. Pin Configuration and Functions
  6. Specifications
    1. 6.1  Absolute Maximum Ratings
    2. 6.2  ESD Ratings
    3. 6.3  ESD Ratings - IEC Specifications
    4. 6.4  Recommended Operating Conditions
    5. 6.5  Thermal Information
    6. 6.6  Power Dissipation Ratings
    7. 6.7  Power Supply Characteristics
    8. 6.8  Electrical Characteristics
    9. 6.9  Timing Requirements
    10. 6.10 Switching Characteristics
    11. 6.11 Typical Characteristics
  7. Parameter Measurement Information
  8. Detailed Description
    1. 8.1 Overview
    2. 8.2 Functional Block Diagram
    3. 8.3 Feature Description
      1. 8.3.1 Supply Pins
        1. 8.3.1.1 VSUP Pin
        2. 8.3.1.2 VCC Pin
        3. 8.3.1.3 VIO Pin
      2. 8.3.2 Digital Inputs and Outputs
        1. 8.3.2.1 TXD Pin
        2. 8.3.2.2 RXD Pin
        3. 8.3.2.3 nFAULT Pin
        4. 8.3.2.4 EN Pin
        5. 8.3.2.5 nSTB Pin
      3. 8.3.3 GND
      4. 8.3.4 INH Pin
      5. 8.3.5 WAKE Pin
      6. 8.3.6 CAN Bus Pins
      7. 8.3.7 Faults
        1. 8.3.7.1 Internal and External Fault Indicators
          1. 8.3.7.1.1 Power-Up (PWRON Flag)
          2. 8.3.7.1.2 Wake-Up Request (WAKERQ Flag)
          3. 8.3.7.1.3 Undervoltage Faults
            1. 8.3.7.1.3.1 Undervoltage on VSUP
            2. 8.3.7.1.3.2 Undervoltage on VCC
            3. 8.3.7.1.3.3 Undervoltage on VIO
          4. 8.3.7.1.4 CAN Bus Fault (CBF Flag)
          5. 8.3.7.1.5 TXD Clamped Low (TXDCLP Flag)
          6. 8.3.7.1.6 TXD Dominant State Timeout (TXDDTO Flag)
          7. 8.3.7.1.7 TXD Shorted to RXD Fault (TXDRXD Flag)
          8. 8.3.7.1.8 CAN Bus Dominant Fault (CANDOM Flag)
      8. 8.3.8 Local Faults
        1. 8.3.8.1 TXD Clamped Low (TXDCLP)
        2. 8.3.8.2 TXD Dominant Timeout (TXD DTO)
        3. 8.3.8.3 Thermal Shutdown (TSD)
        4. 8.3.8.4 Undervoltage Lockout (UVLO)
        5. 8.3.8.5 Unpowered Devices
        6. 8.3.8.6 Floating Terminals
        7. 8.3.8.7 CAN Bus Short-Circuit Current Limiting
    4. 8.4 Device Functional Modes
      1. 8.4.1 Operating Mode Description
        1. 8.4.1.1 Normal Mode
        2. 8.4.1.2 Silent Mode
        3. 8.4.1.3 Standby Mode
        4. 8.4.1.4 Go-To-Sleep Mode
        5. 8.4.1.5 Sleep Mode
          1. 8.4.1.5.1 Remote Wake Request via Wake-Up Pattern (WUP)
          2. 8.4.1.5.2 Local Wake-Up (LWU) via WAKE Input Terminal
      2. 8.4.2 CAN Transceiver
        1. 8.4.2.1 CAN Transceiver Operation
          1. 8.4.2.1.1 CAN Transceiver Modes
            1. 8.4.2.1.1.1 CAN Off Mode
            2. 8.4.2.1.1.2 CAN Autonomous: Inactive and Active
            3. 8.4.2.1.1.3 CAN Active
          2. 8.4.2.1.2 Driver and Receiver Function Tables
          3. 8.4.2.1.3 CAN Bus States
  9. Application Information Disclaimer
    1. 9.1 Application Information
      1. 9.1.1 Typical Application
      2. 9.1.2 Design Requirements
        1. 9.1.2.1 Bus Loading, Length and Number of Nodes
      3. 9.1.3 Detailed Design Procedure
        1. 9.1.3.1 CAN Termination
    2. 9.2 Application Curves
  10. 10Power Supply Recommendations
  11. 11Layout
    1. 11.1 Layout Guidelines
    2. 11.2 Layout Example
  12. 12Device and Documentation Support
    1. 12.1 Documentation Support
    2. 12.2 ドキュメントの更新通知を受け取る方法
    3. 12.3 サポート・リソース
    4. 12.4 商標
    5. 12.5 静電気放電に関する注意事項
    6. 12.6 用語集
  13. 13Mechanical, Packaging, and Orderable Information

パッケージ・オプション

メカニカル・データ(パッケージ|ピン)
サーマルパッド・メカニカル・データ
発注情報
CAN Off Mode

In CAN off mode, the CAN transceiver is switched off and the CAN bus lines are truly floating. In this mode, the device presents no load to the CAN bus while preventing reverse currents from flowing into the device if the battery or ground connection is lost.

The CAN off state is entered if:

  • VSUP < UVSUPF

The CAN transceiver switches between the CAN off state and CAN autonomous inactive mode if:

  • VSUP > UVSUPR