JAJSOV9A March   2023  – December 2023 TMAG5170D-Q1

PRODUCTION DATA  

  1.   1
  2. 特長
  3. アプリケーション
  4. 概要
  5. Pin Configuration and Functions
  6. Specifications
    1. 5.1 Absolute Maximum Ratings
    2. 5.2 ESD Ratings
    3. 5.3 Recommended Operating Conditions
    4. 5.4 Thermal Information
    5. 5.5 Electrical Characteristics
    6. 5.6 Magnetic Characteristics
    7. 5.7 Power up Timing
    8. 5.8 SPI Interface Timing
    9. 5.9 Typical Characteristics
  7. Detailed Description
    1. 6.1 Overview
    2. 6.2 Functional Block Diagram
    3. 6.3 Feature Description
      1. 6.3.1 Magnetic Flux Direction
      2. 6.3.2 Sensor Location
      3. 6.3.3 Magnetic Range Selection
      4. 6.3.4 Update Rate Settings
      5. 6.3.5 ALERT Function
        1. 6.3.5.1 Interrupt and Trigger Mode
        2. 6.3.5.2 Magnetic Switch Mode
      6. 6.3.6 Threshold Count
      7. 6.3.7 Diagnostics
        1. 6.3.7.1  Memory Cyclic Redundancy Check (CRC)
        2. 6.3.7.2  ALERT Integrity Check
        3. 6.3.7.3  VCC Check
        4. 6.3.7.4  Internal LDO Undervoltage Check
        5. 6.3.7.5  Digital Core Power-On Reset Check
        6. 6.3.7.6  SDO Output Check
        7. 6.3.7.7  Communication Cyclic Redundancy Check (CRC)
        8. 6.3.7.8  Oscillator Integrity Check
        9. 6.3.7.9  Magnetic Field Threshold Check
        10. 6.3.7.10 Temperature Alert Check
        11. 6.3.7.11 Analog Front-End (AFE) Check
        12. 6.3.7.12 Hall Resistance and Switch Matrix Check
        13. 6.3.7.13 Hall Offset Check
        14. 6.3.7.14 ADC Check
    4. 6.4 Device Functional Modes
      1. 6.4.1 Operating Modes
        1. 6.4.1.1 Active Mode
        2. 6.4.1.2 Standby Mode
        3. 6.4.1.3 Configuration Mode (DEFAULT)
        4. 6.4.1.4 Sleep Mode
        5. 6.4.1.5 Wake-Up and Sleep Mode
        6. 6.4.1.6 Deep-Sleep Mode
    5. 6.5 Programming
      1. 6.5.1 Data Definition
        1. 6.5.1.1 Magnetic Sensor Data
        2. 6.5.1.2 Temperature Sensor Data
        3. 6.5.1.3 Magnetic Sensor Offset Correction
        4. 6.5.1.4 Angle and Magnitude Data Definition
      2. 6.5.2 Serial Peripheral Interface (SPI)
        1. 6.5.2.1 SCK
        2. 6.5.2.2 CS
        3. 6.5.2.3 SDI
        4. 6.5.2.4 SDO
          1. 6.5.2.4.1 Regular 32-Bit SDO Read
          2. 6.5.2.4.2 Special 32-Bit SDO Read
        5. 6.5.2.5 SPI CRC
        6. 6.5.2.6 SPI Frame
          1. 6.5.2.6.1 32-Bit Read Frame
          2. 6.5.2.6.2 32-Bit Write Frame
  8. Application and Implementation
    1. 7.1 Application Information
      1. 7.1.1 Selecting the Sensitivity Option
      2. 7.1.2 Temperature Compensation for Magnets
      3. 7.1.3 Sensor Conversion
        1. 7.1.3.1 Continuous Conversion
        2. 7.1.3.2 Trigger Conversion
        3. 7.1.3.3 Pseudo-Simultaneous Sampling
      4. 7.1.4 Error Calculation During Linear Measurement
      5. 7.1.5 Error Calculation During Angular Measurement
    2. 7.2 Typical Application
      1. 7.2.1 Design Requirements
        1. 7.2.1.1 Gain Adjustment for Angle Measurement
      2. 7.2.2 Detailed Design Procedure
      3. 7.2.3 Application Curves
    3. 7.3 Best Design Practices
    4. 7.4 Power Supply Recommendations
    5. 7.5 Layout
      1. 7.5.1 Layout Guidelines
      2. 7.5.2 Layout Example
  9. Register Map
  10. Device and Documentation Support
    1. 9.1 ドキュメントの更新通知を受け取る方法
    2. 9.2 サポート・リソース
    3. 9.3 Trademarks
    4. 9.4 静電気放電に関する注意事項
    5. 9.5 用語集
  11. 10Revision History
  12. 11Mechanical, Packaging, and Orderable Information

パッケージ・オプション

メカニカル・データ(パッケージ|ピン)
サーマルパッド・メカニカル・データ
発注情報

Configuration Mode (DEFAULT)

At power up, the TMAG5170D-Q1 goes into the default configuration mode. In this mode, the SPI communication and user register access are enabled. A controller may configure the device to select the desired operating mode, sensor data conversion, enable or disable diagnostic features, and so forth. The average current consumption during this mode is denoted by ICFG. Similar to the standby mode, the configuration mode also supports sensor conversion start with a trigger. However, the configuration mode takes longer time to start the sensor conversion, and consumes approximately ten times less current compared to standby mode.