JAJSOO4B September 2011 – June 2022 TMP100-Q1 , TMP101-Q1
PRODUCTION DATA
PARAMETER | FAST MODE | HIGH-SPEED MODE | UNIT | |||
---|---|---|---|---|---|---|
MIN | MAX | MIN | MAX | |||
f(SCL) | SCL operating frequency | 0.4 | 2 | MHz | ||
t(BUF) | Bus free time between STOP and START condition | 1300 | 160 | ns | ||
t(HDSTA) | Hold time after repeated START condition. After this period, the first clock is generated. | 600 | 160 | ns | ||
t(SUSTA) | Repeated START condition setup time | 600 | 160 | ns | ||
t(SUSTO) | STOP condition setup time | 600 | 160 | ns | ||
t(HDDAT) | Data hold time | 20 | 900 | 20 | 170 | ns |
t(SUDAT) | Data setup time | 100 | 20 | ns | ||
t(LOW) | SCL clock LOW period | 1300 | 360 | ns | ||
t(HIGH) | SCL clock HIGH period | 600 | 60 | ns | ||
tRC, tFC | Clock rise and fall time | 300 | 40 | ns | ||
tRD, tFD | Data rise and fall time | 300 | 170 | ns |