JAJSME8C July   2021  – June 2022 TMP126

PRODUCTION DATA  

  1. 特長
  2. アプリケーション
  3. 概要
  4. Revision History
  5. Device Comparison
  6. Pin Configuration and Functions
  7. 仕様
    1. 7.1 Absolute Maximum Ratings
    2. 7.2 ESD Ratings
    3. 7.3 Recommended Operating Conditions
    4. 7.4 Thermal Information
    5. 7.5 Electrical Characteristics
    6. 7.6 SPI Interface Timing
    7. 7.7 Timing Diagram
    8. 7.8 Typical Characteristics
  8. Detailed Description
    1. 8.1 Overview
    2. 8.2 Functional Block Diagram
    3. 8.3 Feature Descriptions
      1. 8.3.1 Temperature Limits
      2. 8.3.2 Slew Rate Warning
      3. 8.3.3 Cyclic Redundancy Check (CRC)
      4. 8.3.4 NIST Traceability
      5. 8.3.5 Fast Measurement Intervals With No Self-Heating Concerns
    4. 8.4 Device Functional Modes
      1. 8.4.1 Continuous Conversion Mode
      2. 8.4.2 Shutdown Mode
      3. 8.4.3 One-Shot Mode
      4. 8.4.4 Interrupt and Comparator Mode
        1. 8.4.4.1 Interrupt Mode
        2. 8.4.4.2 Comparator Mode
    5. 8.5 Programming
      1. 8.5.1 Temperature Data Format
      2. 8.5.2 Serial Bus Interface
        1. 8.5.2.1 Command Word Structure
          1. 8.5.2.1.1 Don't Care
          2. 8.5.2.1.2 CRC Enable
          3. 8.5.2.1.3 CRC Data Block Length
          4. 8.5.2.1.4 Auto Increment
          5. 8.5.2.1.5 Read/Write
          6. 8.5.2.1.6 Sub-Address
        2. 8.5.2.2 Communication
        3. 8.5.2.3 Write Operations
        4. 8.5.2.4 Read Operations
        5. 8.5.2.5 Cyclic Redundancy Check (CRC)
          1. 8.5.2.5.1 Cyclic Redundancy Check Implementation
    6. 8.6 Register Map
  9. Application and Implementation
    1. 9.1 Application Information
    2. 9.2 Typical Application
      1. 9.2.1 Design Requirements
      2. 9.2.2 Detailed Design Procedure
      3. 9.2.3 Application Curve
  10. 10Power Supply Recommendations
  11. 11Layout
    1. 11.1 Layout Guidelines
    2. 11.2 Layout Example
  12. 12Device and Documentation Support
    1. 12.1 Documentation Support
      1. 12.1.1 Related Documentation
    2. 12.2 Receiving Notification of Documentation Updates
    3. 12.3 サポート・リソース
    4. 12.4 Trademarks
    5. 12.5 Electrostatic Discharge Caution
    6. 12.6 Glossary
  13. 13Mechanical, Packaging, and Orderable Information

パッケージ・オプション

メカニカル・データ(パッケージ|ピン)
サーマルパッド・メカニカル・データ
発注情報

Shutdown Mode

When the Mode bit is set to 1 in the Configuration register, the device immediately enters the low-power shutdown mode. If the TMP126 is making a temperature conversion, the device will stop the conversion and discard the partial result. In this mode, the device powers down all active circuitry and can be used in conjunction with the One_Shot bit to perform temperature conversions. Engineers can use the TMP126 for battery-operated systems and other low-power consumption applications because the device typically only consumes 350 nA in Shutdown Mode.

Changing between continuous and shutdown will not clear any active alerts in the Alert_Status register and the ALERT pin will continue to be asserted until cleared by the host. The slew rate alert will not be triggered again in shutdown mode but will not clear until read if it is already set.