JAJSME8C July   2021  – June 2022 TMP126

PRODUCTION DATA  

  1. 特長
  2. アプリケーション
  3. 概要
  4. Revision History
  5. Device Comparison
  6. Pin Configuration and Functions
  7. 仕様
    1. 7.1 Absolute Maximum Ratings
    2. 7.2 ESD Ratings
    3. 7.3 Recommended Operating Conditions
    4. 7.4 Thermal Information
    5. 7.5 Electrical Characteristics
    6. 7.6 SPI Interface Timing
    7. 7.7 Timing Diagram
    8. 7.8 Typical Characteristics
  8. Detailed Description
    1. 8.1 Overview
    2. 8.2 Functional Block Diagram
    3. 8.3 Feature Descriptions
      1. 8.3.1 Temperature Limits
      2. 8.3.2 Slew Rate Warning
      3. 8.3.3 Cyclic Redundancy Check (CRC)
      4. 8.3.4 NIST Traceability
      5. 8.3.5 Fast Measurement Intervals With No Self-Heating Concerns
    4. 8.4 Device Functional Modes
      1. 8.4.1 Continuous Conversion Mode
      2. 8.4.2 Shutdown Mode
      3. 8.4.3 One-Shot Mode
      4. 8.4.4 Interrupt and Comparator Mode
        1. 8.4.4.1 Interrupt Mode
        2. 8.4.4.2 Comparator Mode
    5. 8.5 Programming
      1. 8.5.1 Temperature Data Format
      2. 8.5.2 Serial Bus Interface
        1. 8.5.2.1 Command Word Structure
          1. 8.5.2.1.1 Don't Care
          2. 8.5.2.1.2 CRC Enable
          3. 8.5.2.1.3 CRC Data Block Length
          4. 8.5.2.1.4 Auto Increment
          5. 8.5.2.1.5 Read/Write
          6. 8.5.2.1.6 Sub-Address
        2. 8.5.2.2 Communication
        3. 8.5.2.3 Write Operations
        4. 8.5.2.4 Read Operations
        5. 8.5.2.5 Cyclic Redundancy Check (CRC)
          1. 8.5.2.5.1 Cyclic Redundancy Check Implementation
    6. 8.6 Register Map
  9. Application and Implementation
    1. 9.1 Application Information
    2. 9.2 Typical Application
      1. 9.2.1 Design Requirements
      2. 9.2.2 Detailed Design Procedure
      3. 9.2.3 Application Curve
  10. 10Power Supply Recommendations
  11. 11Layout
    1. 11.1 Layout Guidelines
    2. 11.2 Layout Example
  12. 12Device and Documentation Support
    1. 12.1 Documentation Support
      1. 12.1.1 Related Documentation
    2. 12.2 Receiving Notification of Documentation Updates
    3. 12.3 サポート・リソース
    4. 12.4 Trademarks
    5. 12.5 Electrostatic Discharge Caution
    6. 12.6 Glossary
  13. 13Mechanical, Packaging, and Orderable Information

パッケージ・オプション

メカニカル・データ(パッケージ|ピン)
サーマルパッド・メカニカル・データ
発注情報

Cyclic Redundancy Check (CRC)

The TMP126 has integrated optional CRC that can be used to determine the integrity of the SPI communication to the TMP126. The CRC is enabled by setting the CRC_Enable bit in the command word to 1 with an appropriate data block length. During a read, the TMP126 will append a 16 bit CRC checksum to the data block for the host to compare with its own checksum. In this manner the host can validate the data sent by TMP126 and read from the device again if necessary. During write operations, the host will send the CRC word that the TMP126 will compare against its own checksum. If the TMP126 determines that the data sent during the write transaction was corrupted, the TMP126 will discard the write and set the CRC_Flag in the Alert_Status register to alert the host that the register settings must be sent again.

This allows the system to ensure the data integrity of the SPI communication in both write and read operations.

Writing to the configuration register with a CRC enabled transaction is currently not supported.