JAJSK89A December 2021 – March 2022 TMP127-Q1
PRODUCTION DATA
Place the power-supply decoupling capacitor as close to the supply and ground pins as possible. The recommended value of this decoupling capacitor is 0.1 µF. Separation between the SCLK trace and the SI/O traces is recommended to reduce coupling of the clock onto the data line.