JAJS465B December   2009  – December 2018 TMP20

PRODUCTION DATA.  

  1. 特長
  2. アプリケーション
  3. 概要
    1.     デバイスのブロック図
    2.     デバイスの温度と静止電流との関係
  4. 改訂履歴
  5. Pin Configuration and Functions
    1.     Pin Functions
  6. Specifications
    1. 6.1 Absolute Maximum Ratings
    2. 6.2 ESD Ratings
    3. 6.3 Recommended Operating Conditions
    4. 6.4 Thermal Information
    5. 6.5 Electrical Characteristics
    6. 6.6 Typical Characteristics
  7. Detailed Description
    1. 7.1 Overview
    2. 7.2 Functional Block Diagram
    3. 7.3 Feature Description
      1. 7.3.1 Transfer Function
        1. 7.3.1.1 Example 1
    4. 7.4 Device Functional Modes
  8. Application and Implementation
    1. 8.1 Application Information
      1. 8.1.1 Output Drive and Capacitive Loads
    2. 8.2 Typical Application
      1. 8.2.1 Design Requirements
      2. 8.2.2 Detailed Design Procedure
      3. 8.2.3 Application Curves
  9. Power Supply Recommendations
  10. 10Layout
    1. 10.1 Layout Guidelines
    2. 10.2 Layout Example
  11. 11デバイスおよびドキュメントのサポート
    1. 11.1 デバイス・サポート
      1. 11.1.1 TINA-TI (無料のダウンロード・ソフトウェア)
        1. 11.1.1.1 TINA-TI SPICEベースのアナログ・シミュレーション・プログラムをTMP20で使用する
      2. 11.1.2 開発サポート
    2. 11.2 ドキュメントの更新通知を受け取る方法
    3. 11.3 コミュニティ・リソース
    4. 11.4 商標
    5. 11.5 静電気放電に関する注意事項
    6. 11.6 Glossary
  12. 12メカニカル、パッケージ、および注文情報

パッケージ・オプション

メカニカル・データ(パッケージ|ピン)
サーマルパッド・メカニカル・データ
発注情報

Electrical Characteristics

over operating free-air temperature range (unless otherwise noted)
PARAMETER TEST CONDITIONS MIN TYP MAX UNIT
TEMPERATURE MEASUREMENT (1)
Accuracy (2) TA = –55°C to 130°C –2.5 2.5 °C
vs supply V+ = 1.8 V to 5.5 V
TA = 15°C to 130°C
–0.05 0.05 °C/V
V+ = 2.7 V to 5.5 V
TA = –50°C to 130°C
–0.05 0.05 °C/V
Temperature sensitivity (3) TA = –30°C to 100°C –12.2 –11.77 –11.4 mV/°C
Output voltage (4) TA = 0°C 1863.9 mV
TA = 25°C 1574
Nonlinearity (5) –20°C ≤ TA ≤ 80°C ±0.4%
ANALOG OUTPUT
Output resistance –600 µA ≤ ILOAD ≤ 600 μA 10
Load regulation –600 µA ≤ ILOAD ≤ 600 μA 6 mV
Maximum capacitive load 1 nF
POWER SUPPLY
VS Specified voltage TA = –55°C to 130°C 2.7 5.5 V
TA = 15°C to 130°C(6) 1.8 5.5
IQ Quiescent current V+ = 5.5 V
TA = 25°C
2.6 4 µA
Over temperature V+ = 5.5 V
TA = –55°C to 130°C
6 µA
ISD Shutdown current V+ < 0.5 V 20 nA
TEMPERATURE RANGE
Specified operating TA = –55°C to 130°C –55 130 °C
TA = 15°C to 130°C(6) 15 130 °C
Operating range V+ = 2.7 V to 5.5 V –55 150 °C
θJA Thermal resistance SC70 185 °C/W
SOT-563 238 °C/W
Self-heating SC70 0.01 °C
SOT-563 0.01 °C
100% production tested at TA = 25°C. Specifications over temperature range are assured by design.
Power-supply rejection is encompassed in the accuracy specification.
Temperature sensitivity is the average slope to the equation VO = (–11.77 × T) + 1.860 V.
VOUT is calculated from temperature with the following equation:
VO = (–3.88 × 10–6 × T2) + (–1.15 × 10–2 × T) + 1.8639 V,
where T is in °C.
Nonlinearity is the deviation of the calculated output voltage from the best fit straight line.
The TMP20 transfer function requires the output voltage to rise above the 1.8-V supply as the temperature decreases below 15°C. When operating at a 1.8-V supply, it is normal for the TMP20 output to approach 1.8 V and remain at that voltage as the temperature continues to decrease below 15°C. This condition does not damage the device. Once the temperature rises above 15°C, the output voltage resumes changing as the temperature changes, according to the transfer function specified in this document. For more information about the transfer function, see .