JAJSO44A June 2023 – September 2024 TMUX582F-SEP
PRODUCTION DATA
デバイスごとのパッケージ図は、PDF版データシートをご参照ください。
Fault response time (tRESPONSE) measures the delay between the source voltage exceeding the fault supply voltage (VFP or VFN) by 0.5V and the drain voltage failing to 50% of the maximum output voltage. Figure 6-9 shows the setup used to measure tRESPONSE.