JAJSQ27 March   2024 TPS22996H-Q1

ADVANCE INFORMATION  

  1.   1
  2. 特長
  3. アプリケーション
  4. 概要
  5. Pin Configuration and Functions
  6. Specifications
    1. 5.1 Absolute Maximum Ratings
    2. 5.2 ESD Ratings
    3. 5.3 Recommended Operating Conditions
    4. 5.4 Thermal Information
    5. 5.5 Electrical Characteristics
    6. 5.6 Switching Characteristics
  7. Parameter Measurement Information
  8. Detailed Description
    1. 7.1 Overview
    2. 7.2 Functional Block Diagram
    3. 7.3 Feature Description
      1. 7.3.1 ON and OFF Control
      2. 7.3.2 Input Capacitor (Optional)
      3. 7.3.3 Output Capacitor (Optional)
      4. 7.3.4 Quick Output Discharge
      5. 7.3.5 Humidity Resistance
      6. 7.3.6 Thermal Shutdown
      7. 7.3.7 Adjustable Rise Time
    4. 7.4 Device Functional Modes
  9. Application and Implementation
    1. 8.1 Application Information
    2. 8.2 Typical Application
      1. 8.2.1 Design Requirements
      2. 8.2.2 Detailed Design Procedure
    3. 8.3 Power Supply Recommendations
    4. 8.4 Layout
      1. 8.4.1 Layout Guidelines
      2. 8.4.2 Layout Example
      3. 8.4.3 Power Dissipation
  10. Device and Documentation Support
    1. 9.1 ドキュメントの更新通知を受け取る方法
    2. 9.2 サポート・リソース
    3. 9.3 Trademarks
    4. 9.4 静電気放電に関する注意事項
    5. 9.5 用語集
  11. 10Revision History
  12. 11Mechanical, Packaging, and Orderable Information

パッケージ・オプション

メカニカル・データ(パッケージ|ピン)
サーマルパッド・メカニカル・データ
発注情報

Absolute Maximum Ratings

over operating free-air temperature range (unless otherwise noted)(1)
MIN MAX UNIT
VIN1,2 Input voltage –0.3 6 V
VOUT1,2 Output voltage –0.3 6 V
VON1,2 ON pin voltage –0.3 6 V
VBIAS Bias voltage –0.3 6 V
IMAX Maximum continuous current per channel 4(2) A
IMAX,PLS Maximum pulsed current switch per channel, pulse < 300µs, 3% duty cycle 5.5 A
TJ Junction temperature 150 °C
Tstg Storage temperature –65 150 °C
Stresses beyond those listed under Absolute Maximum Rating may cause permanent damage to the device. These are stress ratings only, which do not imply functional operation of the device at these or any other conditions beyond those indicated under Recommended Operating Condition. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
For the pre-production units, only 3A of max continuous current per channel is supported. The full released version will support 4A maximum continuous current per channel.