SLUS907K January 2009 – June 2019 TPS2421-1 , TPS2421-2
PRODUCTION DATA.
1. | Calculate maximum RRSET to ensure that minimum ISET is above maximum operating load current using Equation 11 as shown below in Equation 14. |
● | Choose a standard 1% value below RRSET,max for RRSET = 80.6 kΩ | |
● | ISET,min = 2.15 A using Equation 8 meets the maximum operating current requirement of 2.1 A without starting the fault timer during maximum steady state operation for RRSET = 80.6 kΩ, 1%. | |
● | ISET,max = 4.359 A using Equation 9 for RRSET = 80.6 Ω, 1%. | |
2. | Calculate minimum and maximum ILIM. | |
● | ILIM,min = 2.792 A and ILIM,max = 4.359 A using Equation 12 and Equation 13 for RRSET = 80.6 kΩ, 1%. | |
3. | Minimum RLOAD at startup using Equation 6 is 12 Ω. Because RLOAD = 15 Ω is present during circuit startup, use tON = 15 ms from Table 2 for CLOAD = 220 µF and RLOAD = 15 Ω. | |
● | Calculate CCT = 0.48 µF including CLOAD and CCT tolerances (CLOAD_TOL = 20% and CCT_TOL = 10%) using Equation 15. |