SLVSCZ3 March   2015 TPS24770 , TPS24771 , TPS24772

PRODUCTION DATA.  

  1. Features
  2. Applications
  3. Description
  4. Simplified Schematic
  5. Revision History
  6. Device Comparison Table
  7. Pin Configuration and Functions
  8. Specifications
    1. 8.1 Absolute Maximum Ratings
    2. 8.2 ESD Ratings
    3. 8.3 Recommended Operating Conditions
    4. 8.4 Thermal Information
    5. 8.5 Electrical Characteristics
    6. 8.6 Timing Requirements
    7. 8.7 Typical Characteristics
  9. Detailed Description
    1. 9.1 Overview
    2. 9.2 Functional Block Diagram
    3. 9.3 Feature Description
      1. 9.3.1 Enable and Over-voltage Protection
      2. 9.3.2 Current Limit and Power Limit during Start-up
      3. 9.3.3 Two Level Protection During Regular Operation
      4. 9.3.4 Dual Timer (TFLT and TINR)
      5. 9.3.5 3 Options for Response to a Fast Trip
      6. 9.3.6 Using Soft Start - IHGATE and TINR Considerations
      7. 9.3.7 Analog Current Monitor
      8. 9.3.8 Power Good Flag
      9. 9.3.9 Fault Reporting
    4. 9.4 Device Functional Modes
      1. 9.4.1 Hot Swap Functional Modes
  10. 10Application and Implementation
    1. 10.1 Application Information
    2. 10.2 Typical Application
      1. 10.2.1 12 V, 100 A, 5,500 µF Analog Hot Swap Design
      2. 10.2.2 Design Requirements
      3. 10.2.3 Detailed Design Procedure
        1. 10.2.3.1  Select RSNS and VSNS,CL Setting
        2. 10.2.3.2  Selecting the Fast Trip Threshold and Filtering
        3. 10.2.3.3  Selecting the Hot Swap FET(s)
        4. 10.2.3.4  Select Power Limit
        5. 10.2.3.5  Set Fault Timer
        6. 10.2.3.6  Check MOSFET SOA
        7. 10.2.3.7  Choose Under Voltage and Over Voltage Settings
        8. 10.2.3.8  Selecting C1 and COUT
        9. 10.2.3.9  Adding CENHS
        10. 10.2.3.10 Selecting D1 and D2
        11. 10.2.3.11 Checking Stability
        12. 10.2.3.12 Compute Tolerances
      4. 10.2.4 Application Curves
      5. 10.2.5 240 VA Application Using CSD16415Q5B
        1. 10.2.5.1 Design Requirements
        2. 10.2.5.2 Theory of Operations
        3. 10.2.5.3 Design Procedure
          1. 10.2.5.3.1 Select VSNS,CL, RSNS, and RSET Setting
            1. 10.2.5.3.1.1 Select RPOW and RIMON
            2. 10.2.5.3.1.2 Selecting the Hot Swap FET(s)
            3. 10.2.5.3.1.3 Keeping MOSFET within SOA During Normal Start-up
            4. 10.2.5.3.1.4 Choose Fault Timer
            5. 10.2.5.3.1.5 Choose Under Voltage and Over Voltage Settings
            6. 10.2.5.3.1.6 Selecting CIN and COUT
            7. 10.2.5.3.1.7 Selecting D1 and D2
            8. 10.2.5.3.1.8 Adding CENHS
            9. 10.2.5.3.1.9 Stability Considerations
        4. 10.2.5.4 Application Curves
      6. 10.2.6 240 VA Application Using CSD17573Q5B
        1. 10.2.6.1 Design Requirements
          1. 10.2.6.1.1 Choosing C1, COUT, CFLT, CENHS, D1, D2, RSET, RPOW, RIMON, RSNS, CDVDT, RPLIM, and UV/OV Thresholds
          2. 10.2.6.1.2 Selecting the Hot Swap FET(s)
          3. 10.2.6.1.3 Keeping the MOSFET within SOA
        2. 10.2.6.2 Q2 Selection
        3. 10.2.6.3 Application Curves
  11. 11Power Supply Recommendations
  12. 12Layout
    1. 12.1 Layout Guidelines
    2. 12.2 Layout Example
  13. 13Device and Documentation Support
    1. 13.1 Related Links
    2. 13.2 Trademarks
    3. 13.3 Electrostatic Discharge Caution
    4. 13.4 Glossary
  14. 14Mechanical, Packaging, and Orderable Information

パッケージ・オプション

メカニカル・データ(パッケージ|ピン)
サーマルパッド・メカニカル・データ
発注情報

8 Specifications

8.1 Absolute Maximum Ratings

over operating free-air temperature range (unless otherwise noted) (1)
MIN MAX UNIT
Input Voltage VDD,SET, FSTP,SENM, OUTH, ENHS, FLTb, PGHS, OV –0.3 30 V
HGATE to OUTH –0.3 15 V
SET to VDD –0.3 0.3 V
SENM, FSTP to VDD –0.6 0.3 V
TINR, TFLT, PLIM, IMON –0.3 3.6 V
IMONBUF –0.3 7 V
Sink Current FLTb, PGHS 5 mA
Source Current IMON, IMONBUF 5 mA
Storage temperature, Tstg –65 150 °C
(1) Stresses beyond those listed under Absolute Maximum Ratings may cause permanent damage to the device. These are stress ratings only, which do not imply functional operation of the device at these or any other conditions beyond those indicated under Recommended Operating Conditions. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.

8.2 ESD Ratings

VALUE UNIT
V(ESD)(1) Electrostatic discharge Human-body model (HBM), per ANSI/ESDA/JEDEC JS-001(2) ±1500 V
Charged-device model (CDM), per JEDEC specification JESD22-C101(3) ±500
(1) Electrostatic discharge (ESD) measures device sensitivity and immunity to damage caused by assembly line electrostatic discharges into the device.
(2) JEDEC document JEP155 states that 500-V HBM allows safe manufacturing with a standard ESD control process.
(3) JEDEC document JEP157 states that 250-V CDM allows safe manufacturing with a standard ESD control process.

8.3 Recommended Operating Conditions

over operating free-air temperature range (unless otherwise noted)
MIN MAX UNIT
Input voltage VDD, SENM, SET, FSTP 2.5 18 V
ENHS, FLTb, PGHS, OUTH 0 18
Sink current FLTb, PGHS 0 2 mA
Source current IMON 0 1 mA
External resistance PLIM 4.99 500
IMON 1 6
FSTP 10 4000 Ω
SET 10 400 Ω
RIMON / RSET w/o RSTBL 10 70
With appropriate RSTBL(1) 3 10
with CHGATE > 47nF (2) 10 200
External capacitor TINR, TFLT 1 nF
HGATE, (2) 0 1 µF
IMON 30 pF
IMONBUF 100 pF
Operating junction temperature, TJ –40 125 °C
(1) Refer to RSTBL Requirment for RIMON / RSET < 10 as described in section Select RSNS and VSNS,CL Setting.
(2) External capacitance tied to HGATE, should be in series with a resistor no less than 1kΩ.

8.4 Thermal Information

THERMAL METRIC(1) RGE UNIT
24 PINS
RθJA Junction-to-ambient thermal resistance 34.6 °C/W
RθJC(top) Junction-to-case (top) thermal resistance 38.4
RθJB Junction-to-board thermal resistance 12.9
ψJT Junction-to-top characterization parameter 0.5
ψJB Junction-to-board characterization parameter 12.9
RθJC(bot) Junction-to-case (bottom) thermal resistance 3.2
(1) For more information about traditional and new thermal metrics, see the IC Package Thermal Metrics application report, SPRA953.

8.5 Electrical Characteristics

Unless otherwise noted these limits apply to the following: -40°C < TJ<125°C; 2.5V < VVDD, VOUT < 18V; VENHS = 2 V; VOV = 0 V; VHGATE, VPGHS, VFLTB, and VIMONBUF are floating; CINR = 1nF; CFLT = 1nF; RSET = 44.2 Ω; RIMON = 2.98k Ω; RFSTP = 200 Ω; RPLIM = 52 kΩ.
PARAMETER TEST CONDITION MIN TYP MAX UNIT
INPUT SUPPLY (VDD)
VUVR UVLO threshold, rising 2.2 2.32 2.45 V
VUVhyst UVLO hysteresis 0.10 V
IQON Supply current: IVDD + IOUTH Device on, VENHS = 2V 2.95 4 mA
Hot Swap FET ENABLE (ENHS)
VENHS Threshold voltage, rising 1.3 1.35 1.4 V
VENHShyst Hysteresis 50 mV
IENHS Input Leakage Current 0 ≤ VENHS ≤ 30V –1 1 µA
OVER VOLTAGE (OV)
VOVR Threshold voltage, rising 1.3 1.35 1.4 mV
VOVhyst Hysteresis 50 mV
IOV Input leakage current 0 ≤ VOV ≤ 30V –1 1 µA
POWER LIMIT PROGRAMING (PLIM)
VPLIM,BIAS Bias voltage Sourcing 10μA 0.65 0.675 0.7 V
VIMON,PL Regulated IMON voltage during power limit RPLIM = 52 kΩ; VSENM-OUTH=12V 114.75 135 155.25 mV
RPLIM = 105 kΩ; VSENM-OUTH=12V 56.95 67 77.05
RPLIM = 261 kΩ; VSENM-OUTH=12V 18.9 27 35.1
RPLIM = 105 kΩ; VSENM-OUTH=2V 341.7 402 462.3
RPLIM = 105 kΩ; VSENM-OUTH=18V 38.25 45 51.75
SLOW TRIP THRESHOLD (SET)
VOS_SET Input referred offset (VSNS to VIMON scaling) RSET = 44.2Ω; RIMON=3kΩ to 1.2kΩ (VSNS,CL=10mV to 25mV) –150 150 µV
VGE_SET Gain error (VSNS to VIMON scaling)(1) –0.4% 0.4%
FAST TRIP THRESHOLD PROGRAMMING (FSTP)
IFSTP FSTP input bias current VFSTP=12V 95 100 105 µA
VFASTRIP Fast trip threshold RFSTP = 200 Ω, VSNS when VHGATE 18 20 22 mV
RFSTP = 1 kΩ, VSNS when VHGATE 95 100 105
RFSTP = 4 kΩ, VSNS when VHGATE 380 400 420
CURRENT SUMMING NODE (IMON)
VIMON,CL Slow trip threshold at summing node VIMON↑, when ITFLT starts sourcing 660 675 690 mV
IIMON-LKG IMON leakage current VENHS =0V, VIMON = 1.5V –200 200 nA
CURRENT MONITOR (IMONBUF)
VOS_IMONBUF Buffer offset VIMON = 50mV to 675mV, Input referred –3 0 3 mV
GAINIMONBUF Buffer voltage gain ΔVIMONBUF / ΔVIMON 2.97 2.99 3.01 V
BWIMONBUF Buffer closed loop bandwidth CIMONBUF = 75pF 1 MHz
Hot Swap GATE DRIVER (HGATE)
VHGATE HGATE output voltage 5 ≤ VVDD ≤ 16V; measure VHGATE-OUTH 12 13.6 15.5 V
2.5V <VVDD < 5V;
16V <VVDD < 20V measure VHGATE-OUTH
7 7.95 15 V
VHGATEmax Clamp voltage Inject 10μA into HGATE, measure V(HGATE – OUTH) 12 13.9 15.5 V
IHGATEsrc Sourcing current VHGAT-OUTH = 2V-10V 44 55 66 µA
IHGATEfastSink Sinking current for fast trip VHGATE-OUTH = 2V–15V; V(FSTP – SENM) = 20mV 0.45 1 1.6 A
IHGATEsustSink Sustained sinking current Sustained, VHGATE-OUTH = 2V – 15V; VENHS = 0 30 44 60 mA
INRUSH TIMER (TINR)
ITINRsrc Sourcing current VTINR = 0V, In power limit or current limit 8 10.25 12.5 µA
ITINRsink Sinking current VTINR = 2V, In regular operation 1.5 2 2.5 µA
VTINRup Upper threshold voltage Raise VTINR until HGATE starts sinking 1.3 1.35 1.4 V
VTINRlr Lower threshold voltage Raise VTINR to 2V. Reduce VTINR until ITINR is sourcing. 0.33 0.35 0.37 v
RTINR Bleed down resistance VVDD = 0V, VTINR = 2V 70 104 130
ITINR-PD Pulldown current VTINR = 2V, when VENHS = 0V 2 4.2 7 mA
RETRYCYCLE Cycle number # of timer cycles before retry (TPS24771 only) 64 64 64
RETRYDUTY Retry duty cycle TFLT and TINR connected (TPS24771 only) 0.70%
TFLT and TINR not connected (TPS24771 only) 0.35%
VIMON,TINR See Using Soft Start - IHGATE and TINR Considerations RPLIM = 52kΩ, VSENM = 12V, VOUTH = 0 V. Raise IMON voltage and record IMON when TINR starts sourcing current. 47.75 90 132.25 mV
VIMON,PL See Using Soft Start - IHGATE and TINR Considerations RPLIM = 52kΩ, VSENM-OUTH = 12V, Raise IMON voltage and record IMON when IHGATE starts sinking current. 114.75 135 155.25 mV
ΔVIMON,TINR See Using Soft Start - IHGATE and TINR Considerations ΔVIMON,TINR = VIMON,PL - VIMON,TINR 23 45 67 mV
FAULT TIMER (TFLT)
ITFLTsrc Sourcing current VTFLT = 0V, PGHS is high and in overcurrent 8 10.25 12.5 µA
ITFLTsink Sinking current VTFLT = 2V, Not in overcurrent 1.5 2 2.5 µA
VTFLTup Upper threshold voltage Raise VTFLT until HGATE starts sinking 1.3 1.35 1.4 V
RTFLT Bleed down resistance VENHS = 0V, VTFLT = 2V 70 104 130
ITFLT-PD Pulldown current VTFLT = 2V, when VENHS = 0V 2 5.6 7 mA
HOT SWAP OUTPUT (OUTH)
IOUTH, BIAS Input bias current VOUTH = 12V 30 70 µA
FAULT INDICATOR (FLTb)
VOL_FLTb Output low voltage Sinking 2 mA 0.11 0.25 V
IFLTb Input leakage current VFLTb = 0V, 30V –1 0 1 µA
VHSFLT_IMON VIMON threshold to detect Hot Swap FET short VENHS = 0V, Measured VIMON ↑ to GND when FLTb ↓ 88 101 115 mV
VHSFL_hyst Hysteresis 25 mV
HOT SWAP POWER GOOD OUTPUT (PGHS)
VPGHSth PGHS Threshold Measure VSENM-OUTH ↓ when PGHS↑ 170 270 375 mV
VPGHShyst PGHS hysteresis VSENM-OUTH 80 mV
VOL_PGHS PGHS Output low voltage Sinking 2mA 0.11 0.25 V
IPGHS PHGS Input leakage current VPGHS=0V to 30V –1 0 1 µA
THERMAL SHUTDOWN (OTSD)
TOTSD Thermal shutdown threshold Temperature rising 140 °C
TOTSD,HYST Hysteresis 10 °C
(1) Specified by characterization.

8.6 Timing Requirements

PARAMETER TEST CONDITION MIN TYP MAX UNIT
INPUT SUPPLY (VDD)
DEGLUVLO UVLO deglitch Both rising and falling 14 µs
HOT SWAP FET ENABLE (ENHS)
DEGLENHS Deglitch time Both rising and falling 2.2 3.8 5.5 µs
OVER VOLTAGE (OV)
DEGLOV Deglitch time Both rising and falling 2.2 3.9 5.7 µs
FAST TRIP (FSTP)
tFastOffDly Fast turn-off delay V(FSTP – SENM) : –5mV to 5mV, CHGATE = 0 pF 600 ns
V(FSTP – SENM) : -20mV to 20mV CHGATE = 0 pF 300
tFastOffDur Strong pull down current duration 53 63 73 µs
INRUSH TIMER (TINR)
NRETRY Number of TINR cycles before retry TPS24741 only 64
RETRYDUTY Retry duty cycle TINR not connected to TFLT 0.35%
TINR connected to TFLT 0.7%
FAULT INDICATOR (FLTb)
tFLT_degl Fault deglitch Both rising and falling 2.2 3.9 5.3 ms
HOT SWAP POWER GOOD OUTPUT (PGHS)
tPGHSdegl PGHS deglitch time Rising 0.7 1 1.3 ms
Falling 7 8 9

8.7 Typical Characteristics

Unless otherwise noted these cureves apply to the following: -40°C < TJ<125°C; 2.5V < VVDD, VOUT < 18V; VENHS = 2 V; VOV = 0 v; VHGATE, VPGHS, VFLTB, and VIMONBUF are floating; CINR = 1nF; CFLT = 1nF; RSET = 44.2 Ω; RIMON = 2.98k Ω; RFSTP = 200 Ω; RPLIM = 52 kΩ.
TPS24770 TPS24771 TPS24772 C001_SLVSCZ3.png
Iq = IVDD+IOUTH
Figure 1.
TPS24770 TPS24771 TPS24772 C005_SLVSCZ3.png
IPGHS =2mA
Figure 3.
TPS24770 TPS24771 TPS24772 C008_SLVSCZ3.png
Figure 5.
TPS24770 TPS24771 TPS24772 C010_SLVSCZ3.png
VHGATE-VOUTH=10V
Figure 7.
TPS24770 TPS24771 TPS24772 C014_SLVSCZ3.png
Sustained sink current
Figure 9.
TPS24770 TPS24771 TPS24772 C018_SLVSCZ3.png
VHGATE-OUTH=4V
RPLIM =52kΩ
TJ =25°C
Figure 11.
TPS24770 TPS24771 TPS24772 C002_SLVSCZ3.png
Figure 2.
TPS24770 TPS24771 TPS24772 C006_SLVSCZ3.png
Figure 4.
TPS24770 TPS24771 TPS24772 C009_SLVSCZ3.png
VIMON during Power Limiting
Figure 6.
TPS24770 TPS24771 TPS24772 C011_SLVSCZ3.png
VHGATE-VOUTH=2V
Figure 8.
TPS24770 TPS24771 TPS24772 C016_SLVSCZ3.png
Figure 10.