JAJSIO9E March   2014  – June 2021 TPS25200

PRODUCTION DATA  

  1. 特長
  2. アプリケーション
  3. 概要
  4. Revision History
  5. Pin Configuration and Functions
  6. Specifications
    1. 6.1 Absolute Maximum Ratings
    2. 6.2 ESD Ratings
    3. 6.3 Recommended Operating Conditions
    4. 6.4 Thermal Information
    5. 6.5 Electrical Characteristics
    6. 6.6 Timing Requirements
    7. 6.7 Typical Characteristics
  7. Parameter Measurement Information
  8. Detailed Description
    1. 8.1 Overview
    2. 8.2 Functional Block Diagram
    3. 8.3 Feature Description
      1. 8.3.1 Enable
      2. 8.3.2 Thermal Sense
      3. 8.3.3 Overcurrent Protection
      4. 8.3.4 FAULT Response
      5. 8.3.5 Output Discharge
    4. 8.4 Device Functional Modes
      1. 8.4.1 Undervoltage Lockout (UVLO)
      2. 8.4.2 Overcurrent Protection (OCP)
      3. 8.4.3 Overvoltage Clamp (OVC)
      4. 8.4.4 Overvoltage Lockout (OVLO)
  9. Application and Implementation
    1. 9.1 Application Information
    2. 9.2 Typical Application
      1. 9.2.1 Design Requirements
      2. 9.2.2 Detailed Design Procedure
        1. 9.2.2.1 Step by Step Design Produce
        2. 9.2.2.2 Input and Output Capacitance
        3. 9.2.2.3 Programming the Current-Limit Threshold
        4. 9.2.2.4 Design Above a Minimum Current Limit
        5. 9.2.2.5 Design Below a Maximum Current Limit
        6. 9.2.2.6 Power Dissipation and Junction Temperature
      3. 9.2.3 Application Curves
  10. 10Power Supply Recommendations
  11. 11Layout
    1. 11.1 Layout Guidelines
    2. 11.2 Layout Example
  12. 12Device and Documentation Support
    1. 12.1 Documentation Support
      1. 12.1.1 Related Documentation
    2. 12.2 Receiving Notification of Documentation Updates
    3. 12.3 サポート・リソース
    4. 12.4 Trademarks
    5. 12.5 Electrostatic Discharge Caution
    6. 12.6 Glossary
  13. 13Mechanical, Packaging, and Orderable Information

パッケージ・オプション

メカニカル・データ(パッケージ|ピン)
サーマルパッド・メカニカル・データ
発注情報

Design Above a Minimum Current Limit

Some applications require that current limiting cannot occur below a certain threshold. For this example, assume that 2.1 A must be delivered to the load so that the minimum desired current-limit threshold is 2100 mA. Use the IOS equations (Equation 1) and Figure 9-4 to select RILIM as shown in Equation 2.

Equation 2. GUID-C84A0EC4-071C-42A3-874B-FE25FB29F7FE-low.gif

Select the closest 1% resistor less than the calculated value: RILIM = 42.2 kΩ. This sets the minimum current-limit threshold at 2130 mA as shown in Equation 3.

Equation 3. GUID-5623BEA2-DA45-4AA0-BCF9-F272718DEB9B-low.gif

Use the IOS equations (Equation 1), Figure 9-4, and the previously calculated value for RILIM to calculate the maximum resulting current-limit threshold as shown in Equation 4.

Equation 4. GUID-B0E00628-A75B-4714-8A6E-8208459FB957-low.gif

The resulting current-limit threshold minimum is 2130 mA and maximum is 2479 mA with RILIM = 42.2kΩ ± 1%.