JAJSC83E May 2016 – January 2021 TPS25940-Q1
PRODMIX
The TPS25940xx-Q1 eFuse offers robust protection for the 5-V Power rail of USB ports under faults conditions like Short-to-Ground, Short-to-Battery and Overload.
5-V Power rail gets disconnected from the output within approximately 200 ns during short circuit to Ground fault.
The eFuse monitors the reverse voltage from IN to OUT and when it exceeds –66 mV, it stops the flow of reverse current. This operation protects the 5-V power rail from Short-to-Battery faults.
Typical application schematic of TPS25940xx-Q1 usage in USB port protection for automotive application is shown in Figure 10-20.
Figure 10-21 and Figure 10-22 show the performance of TPS25940-Q1 under Short-to-Battery and Short-to-Ground faults.
V(IN) = 5 V | C(OUT) = 4.7 µF |