JAJSOA2 December 2022 TPS25961
PRODUCTION DATA
PIN | I/O | DESCRIPTION | |
---|---|---|---|
NAME | NO. | ||
OUT | 1 | Power | Power output. |
OVLO | 2 | Analog Input | An external resistor divider from supply rail can be used to adjust the overvoltage lockout threshold. Connect to GND directly to use internal fixed overvoltage lockout threshold. Do not leave floating. |
ILIM | 3 | Analog Output | An external resistor from this pin to GND sets the output current limit threshold. Leave it open to set the current limit threshold to minimum value. |
GND | 4 | Ground | Connect to system electrical ground. |
EN/UVLO | 5 | Analog Input | Active High Enable for the device. A resistor divider from supply rail can be used to adjust the undervoltage lockout threshold. Do not leave floating. |
IN | 6 | Power | Power input. |
GND | PAD | Thermal/Ground | The exposed pad is used primarily for heat dissipation and must be connected to GND plane on the PCB. |