JAJSMP7A March   2022  – September 2023 TPS3760

PRODUCTION DATA  

  1.   1
  2. 特長
  3. アプリケーション
  4. 概要
  5. Revision History
  6. Device Comparison
  7. Pin Configuration and Functions
  8. Specifications
    1. 7.1 Absolute Maximum Ratings
    2. 7.2 ESD Ratings
    3. 7.3 Recommended Operating Conditions
    4. 7.4 Thermal Information
    5. 7.5 Electrical Characteristics
    6. 7.6 Timing Requirements
    7. 7.7 Timing Diagrams
    8. 7.8 Typical Characteristics
  9. Detailed Description
    1. 8.1 Overview
    2. 8.2 Functional Block Diagram
    3. 8.3 Feature Description
      1. 8.3.1 Input Voltage (VDD)
        1. 8.3.1.1 Undervoltage Lockout (VPOR < VDD < UVLO)
        2. 8.3.1.2 Power-On Reset (VDD < VPOR )
      2. 8.3.2 SENSE
        1. 8.3.2.1 SENSE Hysteresis
      3. 8.3.3 Output Logic Configurations
        1. 8.3.3.1 Open-Drain
        2. 8.3.3.2 Push-Pull
        3. 8.3.3.3 Active-High (RESET)
        4. 8.3.3.4 Active-Low (RESET)
      4. 8.3.4 User-Programmable Reset Time Delay
        1. 8.3.4.1 Reset Time Delay Configuration
      5. 8.3.5 User-Programmable Sense Delay
        1. 8.3.5.1 Sense Time Delay Configuration
      6. 8.3.6 Manual RESET (CTR / MR) Input
      7. 8.3.7 RESET Latch Mode
    4. 8.4 Device Functional Modes
  10. Application and Implementation
    1. 9.1 Application Information
    2. 9.2 Adjustable Voltage Thresholds
    3. 9.3 Typical Application
      1. 9.3.1 Design 1: Off-Battery Monitoring
        1. 9.3.1.1 Design Requirements
        2. 9.3.1.2 Detailed Design Procedure
        3. 9.3.1.3 Application Curves
  11. 10Power Supply Recommendations
    1. 10.1 Power Dissipation and Device Operation
  12. 11Layout
    1. 11.1 Layout Guidelines
    2. 11.2 Layout Example
    3. 11.3 Creepage Distance
  13. 12Device and Documentation Support
    1. 12.1 Device Nomenclature
    2. 12.2 ドキュメントの更新通知を受け取る方法
    3. 12.3 サポート・リソース
    4. 12.4 Trademarks
    5. 12.5 静電気放電に関する注意事項
    6. 12.6 用語集
  14. 13Mechanical, Packaging, and Orderable Information

パッケージ・オプション

メカニカル・データ(パッケージ|ピン)
サーマルパッド・メカニカル・データ
発注情報

Device Functional Modes

Table 8-4 Undervoltage Detect Functional Mode Truth Table
DESCRIPTIONSENSECTR (1) / MR PINVDD PINOUTPUT (2)
(RESET PIN)
PREVIOUS CONDITIONCURRENT CONDITION
Normal OperationSENSE > VITN(UV)SENSE > VITN(UV)Open or capacitor connectedVDD > VDD(MIN)High
Undervoltage DetectionSENSE > VITN(UV)SENSE < VITN(UV)Open or capacitor connectedVDD > VDD(MIN)Low
Undervoltage DetectionSENSE < VITN(UV)SENSE > VITN(UV)Open or capacitor connectedVDD > VDD(MIN)Low
Normal OperationSENSE < VITN(UV)SENSE > VITN(UV) + HYSOpen or capacitor connectedVDD > VDD(MIN)High
Manual ResetSENSE > VITN(UV)SENSE > VITN(UV)LowVDD > VDD(MIN)Low
UVLO EngagedSENSE > VITN(UV)SENSE > VITN(UV)Open or capacitor connectedVPOR < VDD < VDD(MIN)Low
Below VPOR, Undefined OutputSENSE > VITN(UV)SENSE > VITN(UV)Open or capacitor connectedVDD < VPORUndefined
Reset time delay is ignored in the truth table.
Open-drain active low output requires an external pull-up resistor to a pull-up voltage.
Table 8-5 Overvoltage Detect Functional Mode Truth Table
DESCRIPTIONSENSECTR (1) / MR PINVDD PINOUTPUT (2)
(RESET PIN)
PREVIOUS CONDITIONCURRENT CONDITION
Normal OperationSENSE < VITN(OV)SENSE < VITN(OV)Open or capacitor connectedVDD > VDD(MIN)High
Overvoltage DetectionSENSE < VITN(OV)SENSE > VITN(OV)Open or capacitor connectedVDD > VDD(MIN)Low
Overvoltage DetectionSENSE > VITN(OV)SENSE < VITN(OV)Open or capacitor connectedVDD > VDD(MIN)Low
Normal OperationSENSE > VITN(OV)SENSE < VITN(OV) - HYSOpen or capacitor connectedVDD > VDD(MIN)High
Manual ResetSENSE < VITN(OV)SENSE < VITN(OV)LowVDD > VDD(MIN)Low
UVLO EngagedSENSE < VITN(OV)SENSE < VITN(OV)Open or capacitor connectedVPOR < VDD < UVLOLow
Below VPOR, Undefined OutputSENSE < VITN(OV)SENSE < VITN(OV)Open or capacitor connectedVDD < VPORUndefined
Reset time delay is ignored in the truth table.
Open-drain active low output requires an external pull-up resistor to a pull-up voltage.