JAJSQG3B march 2022 – may 2023 TPS389006-Q1
PRODUCTION DATA
A typical application for the TPS389006-Q1 is shown in Figure 9-1. TPS389006-Q1 is used to provide the proper voltage monitoring for the target SOC device. A multichannel voltage monitor TPS389006-Q1 is used to monitor the voltage rails as these rails power up and power down to ensure that the correct sequence occurs in both occasions. A safety microcontroller is also used to provide ACT, SLEEP, and I2C commands to the TPS389006-Q1 monitor the NIRQ pin for active faults. The ACT signal from the safety microcontroller determines when the TPS389006-Q1 enters into ACTIVE or IDLE states while the NIRQ pin of the TPS389006-Q1 acts as a latched interrupt pin that is set when a fault has occurred. The host microcontroller can clear the fault by writing 1 to the affected register(s). The power rails for the safety microcontroller are not shown in Figure 9-1 for simplicity.