The resistor divider for the ADRSEL pin selects the range of PMBus Addresses and SYNC direction for the TPS546D24S. For Stand Alone devices with only one device supporting a single output voltage, the ADRSEL divider also selects the Phase Shift between SYNC and the switch node.
RESISTOR DIVIDER CODE | DEVICE_ADDRESS | SYNC IN / SYNC OUT | STACK_CONFIG = 0x0000 (STAND-ALONE ONLY) | |
---|---|---|---|---|
— | Range | — | PHASE SHIFT | INTERLEAVE |
Short to AGND | 0x7F (127d) | Auto Detect | 0 | 0x0020 |
Float | EEPROM (0x24h / 36d) | Auto Detect | 0 | 0x0020 |
None | 16d - 31d | Auto detect | 0 | 0x0020 |
0 | 16d - 31d | Sync in | 0 | 0x0040 |
1 | 32d - 47d | Sync in | 0 | 0x0040 |
2 | 16d - 31d | Sync in | 90 | 0x0041 |
3 | 32d - 47d | Sync in | 90 | 0x0041 |
4 | 16d - 31d | Sync in | 120 | 0x0031 |
5 | 32d - 47d | Sync in | 120 | 0x0031 |
6 | 16d - 31d | Sync in | 180 | 0x0042 |
7 | 32d - 47d | Sync in | 180 | 0x0042 |
8 | 16d - 31d | Sync in | 240 | 0x0032 |
9 | 32d - 47d | Sync in | 240 | 0x0032 |
10 | 16d - 31d | Sync in | 270 | 0x0043 |
11 | 32d - 47d | Sync in | 270 | 0x0043 |
12 | 16d - 31d | Sync out | 0 | 0x0020 |
13 | 32d - 47d | Sync out | 0 | 0x0020 |
14 | 16d - 31d | Sync out | 180 | 0x0042 |
15 | 32d - 47d | Sync out | 180 | 0x0042 |
The resistor to AGND for ADRSEL programs the device PMBus loop follower address according to Table 7-15:
RESISTOR TO AGND CODE | DEVICE ADDRESS (16-31 RANGE) | DEVICE ADDRESS (32-47 RANGE) |
---|---|---|
0 | 0x10h (16d) | 0x20h (32d) |
1 | 0x11h (17d) | 0x21h (33d) |
2 | 0x12h (18d) | 0x22h (34d) |
3 | 0x13h (19d) | 0x23h (35d) |
4 | 0x14h (20d) | 0x24h (36d) |
5 | 0x15h (21d) | 0x25h (37d) |
6 | 0x16h (22d) | 0x26h (38d) |
7 | 0x17h (23d) | 0x27h (39d) |
8 | 0x18h (24d) | 0x48h (72d) |
9 | 0x19h (25d) | 0x29h (41d) |
10 | 0x1Ah (26d) | 0x2Ah (42d) |
11 | 0x1Bh (27d) | 0x2Bh (43d) |
12 | 0x1Ch (28d) | 0x2Ch (44d) |
13 | 0x1Dh (29d) | 0x2Dh (45d) |
14 | 0x1Eh (30d) | 0x2Eh (46d) |
15 | 0x1Fh (31d) | 0x2Fh (47d) |
When a TPS546D24S device is configured as the loop controller of a multi-phase stack, the device always occupies the zero-degree position in (37h) INTERLEAVE, but the ADRSEL resistor divider can still be used to select Auto Detect, Forced SYNC_IN, and Forced SYNC_OUT. When the loop controller of a multi-phase stack is configured for SYNC_IN, all devices of the stack remain disabled until a valid external SYNC signal is provided.