JAJSVH7A October   2024  – November 2024 TPS61287

PRODUCTION DATA  

  1.   1
  2. 特長
  3. アプリケーション
  4. 概要
  5. Pin Configuration and Functions
  6. Specifications
    1. 5.1 Absolute Maximum Ratings
    2. 5.2 ESD Ratings
    3. 5.3 Recommended Operating Conditions
    4. 5.4 Thermal Information
    5. 5.5 Electrical Characteristics
    6. 5.6 Typical Characteristics
  7. Detailed Description
    1. 6.1 Overview
    2. 6.2 Functional Block Diagram
    3. 6.3 Feature Description
      1. 6.3.1 Enable and Start-up
      2. 6.3.2 Undervoltage Lockout (UVLO)
      3. 6.3.3 Programmable EN/UVLO
      4. 6.3.4 Switching Valley Current Limit
      5. 6.3.5 External Clock Synchronization
      6. 6.3.6 Stackable Multi-phase Operation
      7. 6.3.7 Device Functional Modes
        1. 6.3.7.1 Forced PWM Mode
        2. 6.3.7.2 Auto PFM Mode
      8. 6.3.8 Overvoltage Protection
      9. 6.3.9 Thermal Shutdown
  8. Application and Implementation
    1. 7.1 Application Information
    2. 7.2 Typical Application
      1. 7.2.1 Design Requirements
      2. 7.2.2 Detailed Design Procedure
        1. 7.2.2.1 Setting Output Voltage
        2. 7.2.2.2 Inductor Selection
        3. 7.2.2.3 Bootstrap And VCC Capacitors Selection
        4. 7.2.2.4 MOSFET Selection
        5. 7.2.2.5 Input Capacitor Selection
        6. 7.2.2.6 Output Capacitor Selection
        7. 7.2.2.7 Loop Stability
      3. 7.2.3 Application Curves
    3. 7.3 Power Supply Recommendations
    4. 7.4 Layout
      1. 7.4.1 Layout Guidelines
      2. 7.4.2 Layout Example
        1. 7.4.2.1 Thermal Considerations
  9. Device and Documentation Support
    1. 8.1 Receiving Notification of Documentation Updates
    2. 8.2 サポート・リソース
    3. 8.3 Trademarks
    4. 8.4 静電気放電に関する注意事項
    5. 8.5 用語集
  10. Revision History
  11. 10Mechanical, Packaging, and Orderable Information

パッケージ・オプション

メカニカル・データ(パッケージ|ピン)
サーマルパッド・メカニカル・データ
発注情報

Auto PFM Mode

In Auto PFM mode , the TPS61287 provides a seamless transition from PWM to PFM operation and enables automatic pulse-skipping mode that provides excellent efficiency over a wide load range. As load current decreasing or VIN rising, the output of the internal error amplifier decreases to lower the inductor valley current, delivering less power to the load. When the output of the error amplifier goes down and reaches a threshold of about 250mA valley current, the output of the error amplifier is clamped at this value and does not decrease any more, the TPS61287 extends its off-time of the switching period to deliver less energy to the output and regulate the output voltage at 1.01 times of the normal value.

.
TPS61287 Auto PFM
                    Mode Diagram Figure 6-5 Auto PFM Mode Diagram