JAJSNJ1H May   2013  – December 2021 TPS65310A-Q1

PRODUCTION DATA  

  1. 特長
  2. アプリケーション
  3. 概要
  4. Revision History
  5. 概要 (続き)
  6. Pin Configuration and Functions
  7. Specifications
    1. 7.1 Absolute Maximum Ratings
    2. 7.2 ESD Ratings
    3. 7.3 Recommended Operating Conditions
    4. 7.4 Thermal Information
    5. 7.5 Electrical Characteristics
    6. 7.6 SPI Timing Requirements
    7. 7.7 Typical Characteristics
  8. Detailed Description
    1. 8.1 Overview
    2. 8.2 Functional Block Diagram
    3. 8.3 Feature Description
      1. 8.3.1 Buck Controller (Buck1)
        1. 8.3.1.1 Operating Modes
        2. 8.3.1.2 Normal Mode PWM Operation
      2. 8.3.2 Synchronous Buck Converters Buck2 And Buck3
      3. 8.3.3 BOOST Converter
      4. 8.3.4 Frequency-Hopping Spread Spectrum
      5. 8.3.5 Linear Regulator LDO
      6. 8.3.6 Gate Driver Supply
    4. 8.4 Device Functional Modes
      1. 8.4.1  RESET
      2. 8.4.2  Soft Start
      3. 8.4.3  INIT
      4. 8.4.4  TESTSTART
      5. 8.4.5  TESTSTOP
      6. 8.4.6  VTCHECK
      7. 8.4.7  RAMP
      8. 8.4.8  Power-Up Sequencing
      9. 8.4.9  Power-Down Sequencing
      10. 8.4.10 Active
      11. 8.4.11 ERROR
      12. 8.4.12 LOCKED
      13. 8.4.13 LPM0
      14. 8.4.14 Shutdown
        1. 8.4.14.1 Power-On Reset Flag
      15. 8.4.15 Wake Pin
      16. 8.4.16 IRQ Pin
      17. 8.4.17 VBAT Undervoltage Warning
      18. 8.4.18 VIN Over Or Undervoltage Protection
      19. 8.4.19 External Protection
      20. 8.4.20 Overtemperature Detection And Shutdown
      21. 8.4.21 Independent Voltage Monitoring
      22. 8.4.22 GND Loss Detection
      23. 8.4.23 Reference Voltage
      24. 8.4.24 Shutdown Comparator
      25. 8.4.25 LED And High-Side Switch Control
      26. 8.4.26 Window Watchdog
      27. 8.4.27 Timeout In Start-Up Modes
    5. 8.5 Programming
      1. 8.5.1 SPI
        1. 8.5.1.1 FSI Bit
    6. 8.6 Register Maps
      1. 8.6.1 Register Description
      2. 8.6.2 NOP0X00
        1. 8.6.2.1  SPI_SCK_FAIL 0x03
        2. 8.6.2.2  LPMO_CMD 0x11
        3. 8.6.2.3  LOCK_CMD 0x12
        4. 8.6.2.4  PWR_STAT 0x21
        5. 8.6.2.5  SYS_STAT 0x22
        6. 8.6.2.6  SPI_STAT 0x23
        7. 8.6.2.7  COMP_STAT 0x24
        8. 8.6.2.8  DEV_REV 0x2F
        9. 8.6.2.9  PWR_CONFIG 0x31
        10. 8.6.2.10 DEV_CONFIG 0x32
        11. 8.6.2.11 CLOCK_CONFIG 0x33
  9. Application and Implementation
    1. 9.1 Application Information
    2. 9.2 Typical Applications
      1. 9.2.1 Buck Controller 1
        1. 9.2.1.1 Design Requirements
        2. 9.2.1.2 Detailed Design Procedure
          1. 9.2.1.2.1 Adjusting the Output Voltage for the BUCK1 Controller
          2. 9.2.1.2.2 Output Inductor, Sense Resistor and Capacitor Selection for the BUCK1 Controller
          3. 9.2.1.2.3 Compensation of the Buck Controller
          4. 9.2.1.2.4 Bootstrap Capacitor for the BUCK1 Controller
        3. 9.2.1.3 BUCK 1 Application Curve
      2. 9.2.2 Synchronous Buck Converters BUCK2 and BUCK3
        1. 9.2.2.1 Design Requirements
        2. 9.2.2.2 Detailed Design Procedure
          1. 9.2.2.2.1 Adjusting the Output Voltage for the BUCK2 and BUCK3 Converter
          2. 9.2.2.2.2 Output Inductor Selection for the BUCK2 and BUCK3 Converter
          3. 9.2.2.2.3 Compensation of the BUCK2 and BUCK3 Converters
          4. 9.2.2.2.4 Bootstrap Capacitor for the BUCK2/3 Converters
        3. 9.2.2.3 Application Curves
      3. 9.2.3 BOOST Converter
        1. 9.2.3.1 Design Requirements
        2. 9.2.3.2 Detailed Design Procedure
          1. 9.2.3.2.1 Adjusting the Output Voltage for the Boost Converter
          2. 9.2.3.2.2 Output Inductor and Capacitor Selection for the BOOST Converter
          3. 9.2.3.2.3 Compensation of the BOOST Converter
          4. 9.2.3.2.4 Output Diode for the BOOST Converter
        3. 9.2.3.3 BOOST Converter Application Curves
      4. 9.2.4 Linear Regulator
        1. 9.2.4.1 Design Requirements
        2. 9.2.4.2 Detailed Design Procedure
          1. 9.2.4.2.1 Adjusting the Output Voltage for the Linear Regulator
          2. 9.2.4.2.2 Output Capacitance for the Linear Regulator
        3. 9.2.4.3 Linear Regulator Application Curve
  10. 10Power Supply Recommendations
  11. 11Layout
    1. 11.1 Layout Guidelines
      1. 11.1.1 Buck Controller
      2. 11.1.2 Buck Converter
      3. 11.1.3 Boost Converter
      4. 11.1.4 Linear Regulator
      5. 11.1.5 Other Considerations
    2. 11.2 Layout Example
  12. 12Device and Documentation Support
    1. 12.1 Documentation Support
      1. 12.1.1 Related Documentation
    2. 12.2 Receiving Notification of Documentation Updates
    3. 12.3 サポート・リソース
    4. 12.4 Trademarks
    5. 12.5 Electrostatic Discharge Caution
    6. 12.6 Glossary
  13. 13Mechanical, Packaging, and Orderable Information

パッケージ・オプション

メカニカル・データ(パッケージ|ピン)
サーマルパッド・メカニカル・データ
発注情報

PWR_STAT 0x21

Figure 8-16 PWR_STAT 0x21
PWR_STAT 0x21
Bit7 Bit6 Bit5 Bit4 Bit3 Bit2 Bit1 Bit0
Default after POR 0 0 0 0 0 0 0 0
Read BUCK_FAIL VREG_FAIL OT_BUCK OT_LDO OT_BOOST LDO_FAIL BOOST_FAIL HS_OL
Write d.c. d.c. d.c. d.c. d.c. d.c. d.c. d.c.
LEGEND: R/W = Read/Write; R = Read only; -n = value after reset
Bit Name Bit No. Description
BUCK_FAIL 7 BUCK power fail flag
0:
1: Power stages shutdown detected caused by OC BUCK1, UV, OV, loss of GND (BOOST + all bucks)
BUCK_FAIL flag is cleared in case the fail condition is not present anymore and the flag is transmitted to the controller.
Bit Name Bit No. Description
VREG_FAIL 6 Internal voltage regulator too low
0:
1: VREG fail
VREG_FAIL flag is cleared in case the fail condition is not present anymore and the flag is transmitted to the controller.
Bit Name Bit No. Description
OT_BUCK 5 BUCK1-3 overtemperature flag
0:
1: IC power stages shutdown due to overtemperature
OT flag is cleared in case the fail condition is not present anymore and the flag is transmitted to the controller.
Bit Name Bit No. Description
OT_LDO 4 LDO overtemperature flag
0:
1: LDO shutdown due to overtemperature
OT flag is cleared in case the fail condition is not present anymore and the flag is transmitted to the controller.
Bit Name Bit No. Description
OT_BOOST 3 BOOST overtemperature flag
0:
1: BOOST shutdown due to overtemperature
OT flag is cleared in case the fail condition is not present anymore and the flag is transmitted to the controller.
Bit Name Bit No. Description
LDO_FAIL 2 LDO under or overvoltage flag
0:
1: LDO out of regulation
LDO_FAIL flag is cleared if there is no undervoltage and no overvoltage and the flag is transmitted to the controller.
Bit Name Bit No. Description
BOOST_FAIL 1 Booster under or overvoltage flag or loss of GND
0:
1: Booster out of regulation
BOOST_FAIL flag is cleared if there is no undervoltage and no overvoltage and the flag was transmitted to the controller.
Bit Name Bit No. Description
HS_OL 0 High-side switch open load condition
0:
1: Open load at high side
Bit indicates current OL condition of high side (no flag)