JAJSGW8B October 2014 – February 2019 TPS735-Q1
PRODUCTION DATA.
デバイスごとのパッケージ図は、PDF版データシートをご参照ください。
The device is disabled under the following conditions:
Table 1 shows the conditions that lead to the different modes of operation.
OPERATING MODE | PARAMETER | |||
---|---|---|---|---|
VIN | VEN | IOUT | TJ | |
Normal mode | VIN > VOUTnom + VDO and VIN > UVLO | VEN > VEN(HI) | IOUT < ILIM | TJ < 165°C |
Dropout mode | UVLO < VIN < VOUTnom + VDO | VEN > VEN(HI) | — | TJ < 165°C |
Disabled mode
(any true condition disables the device) |
VIN < UVLO – Vhys | VEN < VEN(LO) | — | TJ > 165°C |