JAJSRJ9G
March 2012 – October 2023
TPS7A7200
PRODUCTION DATA
1
1
特長
2
アプリケーション
3
概要
4
Pin Configurations
5
Specifications
5.1
Absolute Maximum Ratings
5.2
ESD Ratings
5.3
Recommended Operating Conditions
5.4
Thermal Information
5.5
Electrical Characteristics
5.6
Typical Characteristics
6
Detailed Description
6.1
Overview
6.2
Functional Block Diagram
6.3
Feature Description
6.3.1
User-Configurable Output Voltage
6.3.2
Traditional Adjustable Configuration
6.3.3
Undervoltage Lockout (UVLO)
6.3.4
Soft-Start
6.3.5
Current Limit
6.3.6
Enable
6.3.7
Power-Good
6.4
Device Functional Modes
6.4.1
Normal Operation
6.4.2
Dropout Operation
6.4.3
Disabled
7
Application and Implementation
7.1
Application Information
7.2
Typical Application
7.2.1
Design Requirements
7.2.2
Detailed Design Procedure
7.2.2.1
ANY-OUT Programmable Output Voltage
7.2.2.2
Traditional Adjustable Output Voltage
7.2.2.3
Input Capacitor Requirements
7.2.2.4
Output Capacitor Requirements
7.2.3
Application Curves
7.3
Power Supply Recommendations
7.4
Layout
7.4.1
Layout Guidelines
7.4.1.1
Thermal Considerations
7.4.1.2
Power Dissipation
7.4.1.3
Estimating Junction Temperature
7.4.2
Layout Example
8
Device And Documentation Support
8.1
Documentation Support
8.1.1
Related Documentation
8.2
ドキュメントの更新通知を受け取る方法
8.3
サポート・リソース
8.4
Trademarks
8.5
静電気放電に関する注意事項
8.6
用語集
9
Revision History
10
Mechanical, Packaging, And Orderable Information
パッケージ・オプション
メカニカル・データ(パッケージ|ピン)
RGW|20
MPQF122C
RGT|16
MPQF119H
サーマルパッド・メカニカル・データ
RGT|16
QFND098S
発注情報
jajsrj9g_oa
jajsrj9g_pm
5.2
ESD Ratings
VALUE
UNIT
V
(ESD)
Electrostatic discharge
Human-body model (HBM), per ANSI/ESDA/JEDEC JS-001
(1)
±2000
V
Charged-device model (CDM), per JEDEC specification JESD22-C101
(2)
±500
(1)
JEDEC document JEP155 states that 500-V HBM allows safe manufacturing with a standard ESD control process.
(2)
JEDEC document JEP157 states that 250-V CDM allows safe manufacturing with a standard ESD control process.