7.1 Absolute Maximum Ratings(1)
Over operating free-air temperature range (unless otherwise noted)
|
VALUE |
UNIT |
MIN |
MAX |
Pin voltage (2) |
VIN |
–0.3 |
6 |
V |
|
EN, CTRL, VSEL1, VSEL2, VSEL3 |
–0.3 |
VIN +0.3V |
V |
|
VOUT, LOAD |
–0.3 |
3.7 |
V |
Operating ambient temperature range, TA(3) |
-40 |
85 |
°C |
Operating junction temperature TJ |
-40 |
125 |
°C |
Storage temperature, Tstg |
–55 |
125 |
(1) Stresses beyond those listed under absolute maximum ratings may cause permanent damage to the device. These are stress ratings only and functional operation of the device at these or any other conditions beyond those indicated under recommended operating conditions is not implied. Exposure to absolute–maximum–rated conditions for extended periods may affect device reliability.
(2) All voltage values are with respect to network ground terminal GND.
(3) In applications where ambient temperature (TA) constantly stays above 70°C, the product life time might degrade. MLCC capacitor reliability and lifetime is depending on temperature and applied voltage conditions. At higher temperatures, MLCC capacitors are subject to stronger stress. The most critical parameter is the Insulation Resistance (IR) resulting in leakage current.