SLVSCE3A June 2014 – June 2014 TPS82740A , TPS82740B
PRODUCTION DATA.
デバイスごとのパッケージ図は、PDF版データシートをご参照ください。
When the device is enabled, the internal reference is powered up and after the startup delay time tStartup_delay has expired, the device enters softstart, starts switching and ramps up the output voltage. During softstart, the device operates with a reduced current limit, ILIM_softstart, of typ. 1/3 of the nominal current limit. This reduced current limit is active during the time tSoftstart. The current limit is increased to its nominal value, ILIMF, once this time has expired or the nominal output voltage is reached.