JAJSG04A August 2018 – June 2021 TPSM831D31
PRODUCTION DATA
The VOUT_UV_FAULT_RESPONSE instructs the device on what action to take in response to an output undervoltage fault.
Upon triggering the undervoltage fault, the device:
The VOUT_UV_FAULT_RESPONSE command must be accessed through Read Byte/Write Byte transactions.
The VOUT_UV_FAULT_RESPONSE command is shared between Channel A and Channel B. All transactions to this command affects both channels regardless of the PAGE command.
7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 |
RW | RW | RW | RW | RW | RW | RW | RW |
VO_UV_RESP |
LEGEND: R/W = Read/Write; R = Read only |
Bit | Field | Type | Reset | Description |
---|---|---|---|---|
7:0 | VO_UV_RESP | RW | NVM | 00h: Ignore. The controller sets the appropriate status bits, and alerts the host, and continues converting power. BAh: Shutdown and restart. The controller shuts down the channel on which the fault occurred, and attempts to restart after a delay of 20 ms. This process occurs continuously until the condition causing the fault has been removed, or the controller has been disabled. 80h: Latch-off and do not restart. To clear a shutdown event due to a fault event, the user must toggle the AVR_EN/BEN pin and/or the ON bit in OPERATION, per the settings in ON_OFF_CONFIG, or power cycle the bias power to the V3P3 pin of the controller device. |