JAJSG68A September   2018  – December 2018 TUSB217-Q1

PRODUCTION DATA.  

  1. 特長
  2. アプリケーション
  3. 概要
    1.     Device Images
      1.      概略回路図
  4. 改訂履歴
  5. Pin Configuration and Functions
    1.     Pin Functions
  6. Specifications
    1. 6.1 Absolute Maximum Ratings
    2. 6.2 ESD Ratings
    3. 6.3 Recommended Operating Conditions
    4. 6.4 Thermal Information
    5. 6.5 Electrical Characteristics
    6. 6.6 Switching Characteristics
    7. 6.7 Timing Requirements
  7. Detailed Description
    1. 7.1 Overview
    2. 7.2 Functional Block Diagram
      1. 7.2.1 Functional Block Diagram
    3. 7.3 Feature Description
      1. 7.3.1 High speed boost
      2. 7.3.2 RX Sensitivity
    4. 7.4 Device Functional Modes
      1. 7.4.1 Low Speed (LS) mode
      2. 7.4.2 Full Speed (FS) mode
      3. 7.4.3 High Speed (HS) mode
      4. 7.4.4 High Speed downstream port electrical compliance test mode
      5. 7.4.5 Shutdown mode
      6. 7.4.6 I2C mode
    5. 7.5 TUSB217 Registers
      1. 7.5.1 EDGE_BOOST Register (Offset = 0x1) [reset = X]
        1. Table 4. EDGE_BOOST Register Field Descriptions
      2. 7.5.2 CONFIGURATION Register (Offset = 0x3) [reset = X]
        1. Table 5. CONFIGURATION Register Field Descriptions
      3. 7.5.3 DC_BOOST Register (Offset = 0xE) [reset = X]
        1. Table 6. DC_BOOST Register Field Descriptions
      4. 7.5.4 RX_SEN Register (Offset = 0x25) [reset = X]
        1. Table 7. RX_SEN Register Field Descriptions
  8. Application and Implementation
    1. 8.1 Application Information
    2. 8.2 Typical Application
      1. 8.2.1 Design Requirements
      2. 8.2.2 Detailed Design Procedure
        1. 8.2.2.1 Test Procedure to Construct USB High Speed Eye Diagram
          1. 8.2.2.1.1 For a Host Side Application
          2. 8.2.2.1.2 For a Device Side Application
      3. 8.2.3 Application Curves
  9. Power Supply Recommendations
  10. 10Layout
    1. 10.1 Layout Guidelines
    2. 10.2 Layout Example
  11. 11デバイスおよびドキュメントのサポート
    1. 11.1 ドキュメントのサポート
    2. 11.2 ドキュメントの更新通知を受け取る方法
    3. 11.3 コミュニティ・リソース
    4. 11.4 商標
    5. 11.5 静電気放電に関する注意事項
    6. 11.6 Glossary
  12. 12メカニカル、パッケージ、および注文情報

パッケージ・オプション

デバイスごとのパッケージ図は、PDF版データシートをご参照ください。

メカニカル・データ(パッケージ|ピン)
  • RGY|14
サーマルパッド・メカニカル・データ
発注情報

Application Curves

TUSB217-Q1 PRE_NEAR_EYE_SETUP.gifFigure 8. Near End Eye Measurement Set up With Pre-channel Cable
TUSB217-Q1 217_6IN_NO217.gif
Figure 9. 6 inches without TUSB217-Q1
TUSB217-Q1 217_PRE_6IN_L0_HIGH.gif
Figure 11. 6 inches pre-channel with TUSB217-Q1 BOOST=0 RX_SEN=HIGH
TUSB217-Q1 217_PRE_6IN_L0_MED.gif
Figure 10. 6 inches pre-channel with TUSB217-Q1 BOOST=0 RX_SEN=MED
TUSB217-Q1 217_3M_NO217.gif
Figure 12. 3 meter without TUSB217-Q1
TUSB217-Q1 217_PRE_3M_L0_MED.gif
Figure 13. 3 meter pre-channel with TUSB217-Q1 BOOST=0 RX_SEN=MED
TUSB217-Q1 217_2M_NO217.gif
Figure 15. 2 meter without TUSB217-Q1
TUSB217-Q1 217_PRE_2M_L1_HIGH.gif
Figure 17. 2 meter pre-channel with TUSB217-Q1 BOOST=1 RX_SEN=HIGH
TUSB217-Q1 217_PRE_5M_L1_MED.gif
Figure 19. 5 meter pre-channel with TUSB217-Q1 BOOST=1 RX_SEN=MED
TUSB217-Q1 217_PRE_2M_L1_HIGH.gif
Figure 14. 3 meter pre-channel with TUSB217-Q1 BOOST=0 RX_SEN=HIGH
TUSB217-Q1 217_PRE_2M_L1_MED.gif
Figure 16. 2 meter pre-channel with TUSB217-Q1 BOOST=1 RX_SEN=MED
TUSB217-Q1 217_5M_NO217.gif
Figure 18. 5 meter without TUSB217-Q1
TUSB217-Q1 217_PRE_5M_L1_HIGH.gif
Figure 20. 5 meter pre-channel with TUSB217-Q1 BOOST=1 RX_SEN=HIGH
TUSB217-Q1 POST_NEAR_EYE_SETUP.gifFigure 21. Near end eye measurement set up with post-channel cable
TUSB217-Q1 217_6IN_NO217.gif
Figure 22. 6 inches without TUSB217-Q1
TUSB217-Q1 217_POST_6IN_L0_HIGH.gif
Figure 24. 6 inches post-channel with TUSB217-Q1 BOOST=0 RX_SEN=HIGH
TUSB217-Q1 217_POST_6IN_L0_MED.gif
Figure 23. 6 inches post-channel with TUSB217-Q1 BOOST=0 RX_SEN=MED
TUSB217-Q1 217_1M_NO217.gif
Figure 25. 1 meter without TUSB217-Q1
TUSB217-Q1 217_POST_1M_L0_MED.gif
Figure 26. 1 meter post-channel with TUSB217-Q1 BOOST=0 RX_SEN=MED
TUSB217-Q1 217_2M_NO217.gif
Figure 28. 2 meter without TUSB217-Q1
TUSB217-Q1 217_POST_2M_L1_HIGH.gif
Figure 30. 2 meter post-channel with TUSB217-Q1 BOOST=1 RX_SEN=HIGH
TUSB217-Q1 217_POST_4M_L1_MED.gif
Figure 32. 4 meter post-channel with TUSB217-Q1 BOOST=1 RX_SEN=MED
TUSB217-Q1 217_POST_1M_L0_HIGH.gif
Figure 27. 1 meter post-channel with TUSB217-Q1 BOOST=0 RX_SEN=HIGH
TUSB217-Q1 217_POST_2M_L1_MED.gif
Figure 29. 2 meter post-channel with TUSB217-Q1 BOOST=1 RX_SEN=MED
TUSB217-Q1 217_4M_NO217.gif
Figure 31. 4 meter without TUSB217-Q1
TUSB217-Q1 217_POST_4M_L1_HIGH.gif
Figure 33. 4 meter post-channel with TUSB217-Q1 BOOST=1 RX_SEN=HIGH