JAJSCO5C November 2016 – June 2018 TUSB422
PRODUCTION DATA.
デバイスごとのパッケージ図は、PDF版データシートをご参照ください。
7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 |
Reserved | FORCE_VBUS_MASK | AUTO_DISC_FAIL_MASK | FORCE_DISC_FAIL_MASK | VBUS_OCP_FAIL_STATUS_MASK | VBUS_OVP_FAIL_STATUS_MASK | VCONN_OCP_FAULT_STATUS_MASK | I2C_INT_ERR_STATUS_MASK |
R/W | R/W | R/W | R/W | R/W | R/W | R/W | R/W |
LEGEND: R/W = Read/Write; R = Read only |
Bit | Field | Type | Reset | Description |
---|---|---|---|---|
7 | Reserved | R/W | 0 | Reserved |
6 | FORCE_VBUS_MASK | R/W | 1 | Force Off VBUS Interrupt Status Mask
0b: Interrupt masked 1b: Interrupt unmasked |
5 | AUTO_DISC_FAIL_MASK | R/W | 1 | Auto Discharge Failed Mask
0b: Interrupt masked 1b: Interrupt unmasked |
4 | FORCE_DISC_FAIL_MASK | R/W | 1 | Force Discharge Failed Mask
0b: Interrupt masked 1b: Interrupt unmasked |
3 | VBUS_OCP_FAIL_STATUS_MASK | R/W | 1 | Internal or External OCP VBUS Over Current Protection Fault Interrupt Status Mask
0b: Interrupt masked 1b: Interrupt unmasked For TUSB422 this field has no meaning. |
2 | VBUS_OVP_FAIL_STATUS_MASK | R/W | 1 | Internal or External OVP VBUS Over Voltage Protection Fault Interrupt Status Mask
0b: Interrupt masked 1b: Interrupt unmasked For TUSB422 this field has no meaning. |
1 | VCONN_OCP_FAULT_STATUS_MASK | R/W | 1 | V(VCONN) Over Current Fault Interrupt Status Mask
0b: Interrupt masked 1b: Interrupt unmasked |
0 | I2C_INT_ERR_STATUS_MASK | R/W | 1 | I2C Interface Error Interrupt Status Mask
0b: Interrupt masked 1b: Interrupt unmasked |